Appendix D. Logging ACS Robotics Motion 609
1st ed., 6/30/04 - 312579601
Logging Interval
When LMU 3.0 or 9315/9330 1.0 µ-software is properly installed in the ACS, the HSC
identifies hard fails in LLG1 records and records robotic motion and temporary error
counts in LLG6 records written to SYS1.LOGREC.
An LLG6 record is written to SYS1.LOGREC for each qualified ACS at the same interval
that is defined for writing ACS-specific SMF records. A record is written not less than
once in 24 hours, and always when the HSC is shutting down normally (assuming it has
not been canceled).
An LLG1 record, which may or may not represent a hard fail, is written to
SYS1.LOGREC for most operations requested by the HSC for which the LMU is unable
to complete the HSC request. Operations that are automatically retried by the HSC are
usually not errors, and some other states may be defined that are not logged as errors. See
“LMU Response Codes” on page 611 for information on error and response codes. For
62-67 VOLSER of cartridge (this field is only valid if
Request type, byte 59, is ‘B’, ‘C’, ‘D’ or ‘E’
and byte 60 has value character ‘1’)
68-89 Proprietary data
90-91 Host ID
92-94 Sequence number
95-95 Character ‘7’ indicates an error response
96-96 Response type,
‘B’ = Mount response
‘C’ = Dismount response
‘D’ = Swap response
‘E’ = Move response
‘K’ = Catalog response
‘X’ = View response
97-100 LMU Response Code (see Appendix A for
definitions)
101-102 LSMid in error
103-112 Proprietary data
113-113 Character ‘H’ indicates a hard failure
114-641 Reserved
642-643 Record type X’6501’
644-647 StorageTek identifier X’FEEDFACE’
648-651 Timestamp
Table 68. Record Format for a Hard Failure (Continued)
Motion Hard Fail Software Error Record
BYTE # Description of Field