StorageTek 6 Water System User Manual


 
Chapter 4. Utility Functions 337
1st ed., 6/30/04 - 312579601
Invoking the Volume Report Utility
Depending upon the environment in which it is being run, the Volume Report utility can
be invoked in one of two ways:
SLUVOLR EXEC (CMS)
ACSUTIL SLKJCL file (SCP).
SLUVOLR EXEC (CMS)
The user can invoke the utility under CMS by running the SLUVOLR EXEC.
SLUVOLR fn ft fm
where:
fn, ft, fm
the parameter file description. If omitted, fn defaults to ‘‘SLUVOLR,’’ ft defaults to
‘‘PARMS,’’ and fm defaults to ‘‘*.’’ No placeholders are allowed for unspecified
parameters.
Parameter File
A parameter file for the Volume Report running under CMS contains statements similar to
those used to execute the utility under SCP. An example of a parameter file follows.
PARM MIXED
* SLSCDATA SLSCDATA DATA A
SLSSCRPL SCRPOOL STMTS A
SLSCNTL 160 DSN SLS200.SLSD.DBASEPRM
SLSPRINT PRINTER
SLSIN VOL(C84107)
Under SCP, the user can invoke the utility by entering the following command:
EXEC ACS UTIL VOLRpt
Execution of the statement results in the ACSUTIL SLKJCL file:
ACSUTIL SLKJCL File
/JOB jobname SLUADMIN
/PARM MIXED
/FILE SLSCNTL DEV vaddr DSN control.set.name
/FILE SLSPRINT DEV PRNT CLASS A
/FILE SLSVA DEV vaddr DSN <control.set.name> VOL <volume.name>
/FILE SLSIN *
* VOLRPT ACS(ascid) LSM(lsmlist)
* VOLRPT VOLSER(vol!list)
Volume Report