StorageTek 6 Water System User Manual


 
Chapter 4. Utility Functions 207
1st ed., 6/30/04 - 312579601
INTRANs
optionally specifies that in-transit cartridges in an LSM are to be processed. All
in-transit cartridges, except those identified in the note below, are read and ejected as
part of an AUDIt utility operation.
Notes:
1. INTRANs is mutually exclusive with the APPLY(NO) parameter. It can be
used in combination with all other AUDIt parameters.
2. Only the first two cells (columns 0 and 1) in a 9310 playground are accessible
to an in-transit audit. Cartridges in other cell positions in a 9310 playground
(columns 2 through 5) cannot be ejected by an in-transit operation.
3. 9740 diagnostic cells cannot be scanned by an audit.
JCL Requirements
The following definitions apply to Audit utility JCL:
SLSPRINT
output messages from the utility program.
SLSIN
input to the utility in the form of control cards.
Invoking the Audit Utility
The easiest way to run utilities is to execute the ACS UTIL exec by entering the following
command:
EXEC ACS UTIL AUDIT
Execution of the statement results in the ACSUTIL SLKJCL file:
ACSUTIL SLKJCL File
To execute the utility:
1. Delete the lines in the template that are not required, or leave the comment indicator
(*) in column one.
2. Remove the comment indicator from the desired lines.
/JOB jobname SLUADMIN
/PARM MIXED
/FILe SLSPRINT DEV PRNT CLASS A
/FILE SLSIN *
* AUDIT ALL APPLY (YES)
* AUDIT ACS(acsid) LSM(lsm-list) PANEL(panel-list) CAP(capid) -
* ROW(row-list) COLUMN(col-list) APPLY(YES)
Audit