StorageTek 6 Water System User Manual


 
Chapter 4. Utility Functions 315
1st ed., 6/30/04 - 312579601
ACS and Host ID) not specified here will be deleted and no longer
available for use.
2. To remove station addresses for an ACS or host, do not specify station
addresses following the SLISTATN parameter. For example
SET SLISTATN(),FORACS(#1),FORHOST(HSCA)
FORACS
specifies the ACS for which station addresses are being changed. (acs-id) specifies
the ACSid whose stations are being changed (00 - FF).
FORHOST
specifies that the operation is being restricted to a specific host. Only the specified
hosts’ stations are set. If omitted, the stations for all hosts are changed.
(host-id)
specifies the 1- to 8-character host ID for the host to which the operation is
restricted.
SET SMF Record Type
SMF
specifies that the SMF record type used by the HSC is to be set. Until the HSC is
brought down and back up on all CPUs, the Activities Report utility produces
incorrect results. This is because some HSCs are writing records with the old SMF
record type, and some with the new record type.
(libtype)
specifies the SMF record type. The range is from 0 to 255, inclusive. Since 128
through 255 are for user-defined records, it is recommended that a number from
128 through 255 be chosen, and that the number does not conflict with other
user-defined record types.
SET Recovery Technique
TCHNIQE
specifies that the control data set recovery technique is to be set. This SET utility
replaces the recovery technique that is currently defined in the CDS. Refer to
‘‘SLIRCVRY Macro’’ in the HSC Installation Guide for a complete description of
the LIBGEN SLIRCVRY macro. A recovery technique value must be specified;
there is no default value.
NONE
specifies no form of recovery is used for the control data set. Thus, the primary
control data set must be rebuilt, if inaccessible.
JOURNAL
specifies that there is to be only one primary control data set and that journals
are kept. These data sets are to be used for recovery purposes.
Set