StorageTek 6 Water System User Manual


 
Chapter 4. Utility Functions 317
1st ed., 6/30/04 - 312579601
SLSCNTL
the primary control data set. A primary control data set is required.
SLSCNTL2
the secondary control data set. This statement is used only if you have configured
and initiated a secondary control data set for your installation. A secondary control
data set is optional, but highly recommended.
SLSSTBY
the standby control data set. This statement is used only if you have configured and
initiated a standby control data set for your installation. SLSIN input to the utility in
the form of control cards.
Invoking the Set Utility
The easiest way to run utilities is to execute the ACS UTIL exec by entering the following
command:
EXEC ACS UTIL SET
Execution of the statement results in the ACSUTIL SLKJCL file:
ACSUTIL SLKJCL File
To execute the utility:
1. Delete the lines in the template that are not required, or leave the comment indicator
(*) in column one.
2. Remove the comment indicator from the desired lines.
3. Specify values for the desired parameters.
4. Delete the parameters that are not desired.
5. Enter the command ‘‘FILE.’’
The job file is then submitted to the ACS service machine for execution.
/JOB jobname SLUADMIN
/PARM MIXED
/FILE SLSPRINT DEV PRNT CLASS A
/FILE SLSCNTL DEV <500> DSN <dsname>
/FILE SLSCNTL2 DEV <501> DSN <dsname>
/FILE SLSSTBY DEV <vaddr> DSN <dsname>
/FILE SLSIN *
* SET COMPRFX(cmdhex)
Set