Chapter 3. HSC Control Statements and HSC Start Procedure 155
1st ed., 6/30/04 - 312579601
Syntax
Control Statement Name
VOLDEF
initiates the VOLDEF command and control statement.
Parameters
DATASET or DSN
specifies the name of the data set containing the VOLATTR statements to be
processed and, optionally, an OPTion TITLE statement. (Refer to “Volume Attribute
(VOLATTR) Control Statement” on page 143 and “OPTion TITLE Control
Statement” on page 113 for details on syntax and parameters).
Note: The definition data set may contain VOLATTR, UNITATTR, TAPEREQ, and
OPTion TITLE statements.
• Only OPTion TITLE and VOLATTR statements are processed.
• If any other statement is encountered, an error message is issued and the
statement is ignored.
dataset.name
is the name of the data set containing volume attribute parameters. If the data
set name includes a member name, dataset.name must be enclosed in quotes.
For example,
DATASET(‘YOUR.DSN(MEMBER)’)
VOLume
specifies the serial number of the DASD volume on which the data set resides. This
parameter is optional. Specify the VOLume parameter if the data set is not cataloged,
or if a data set on a volume other than the volume indicated by the catalog is to be
used.
Note: The volume specified must be a DASD volume.
volser
specifies the volume serial number for the definition data set.
VOLDEF
DSN(dataset.name)
DATASET(dataset.name)
VOLume(volser) UNIT(unitname)
HOSTID( host-id
,
)
VOLDEF