StorageTek 6 Water System User Manual


 
Appendix C. Record Formats 587
1st ed., 6/30/04 - 312579601
123
(7B) HEXSTRING 3 -RESERVED- * RESERVED
126
(7E) HEXSTRING 6 VOLSRCE SOURCE LOCATION
132
(84) HEXSTRING 6 VOLDEST DESTINATION LOCATION
138
(8A) CHARACTER 2 VOLLILSM “LOST IN” LSM
140
(8C) CHARACTER 8 VOLRECC RECTECH CHAR FORM
148
(94) CHARACTER 8 VOLMEDC MEDIA CHAR FORM
156
(9C) LENGTH VOLIELEN LENGTH OF MAIN VOLUME
SECTION PLUS
IN-TRANSIT/ERRANT
INFORMATION
THE VOLSRCE AND VOLDEST FIELDS MAY BE MAPPED BY THE FOLLOWING DSECT.
0
(0) STRUCTURE VOLLOC
0
(0) CHARACTER 1 VOLSTYPE SOURCE TYPE
‘1’
(F1) CHAR CONST VOLSCELL CELL
‘2’
(F2) CHAR CONST VOLSCAP CAP
‘3’
(F3) CHAR CONST VOLSDRIV DRIVE
‘4’
(F4) CHAR CONST VOLSOTHR OTHER
1
(1) HEXSTRING 1 VOLSACSN ACS NUMBER
2
(2) HEXSTRING 1 VOLSLSMN LSM NUMBER
******************
FOR “CELL” TYPES
******************
3
(3) HEXSTRING 1 VOLSPNLN PANEL NUMBER
4
(4) HEXSTRING 1 VOLSROWN ROW NUMBER
5
(5) HEXSTRING 1 VOLSCOLN COLUMN (CELL) NUMBER
*****************
FOR “CAP” TYPES
*****************
3
(3) HEXSTRING 2 VOLSCLOC CAP LOCATION
5
(5) HEXSTRING 1 -RESERVED- RESERVED
*******************
FOR “DRIVE” TYPES
*******************
3
(3) HEXSTRING 1 VOLSDPNL DRIVE PANEL NUMBER
4
(4) HEXSTRING 1 VOLSDNUM DRIVE NUMBER
Table 63. SLUVVDAT Record Format (Continued)
Dec Hex Type Length Label Description