116 VM/HSC 6.0 System Programmer’s Guide
1st ed., 6/30/04 - 312579601
4. For additional information about syntax, refer to “Control Statement Syntax
Conventions” on page 439.
Syntax
Control Statement Name
SCRPDEF
initiates the SCRPDEF command and control statement.
Parameters
DATASET or DSN
specifies the name of the data set containing the SCRPOol statements to be processed
and, optionally, an OPTion TITLE statement. (Refer to “Scratch Subpool Control
Statement” on page 100 and “OPTion TITLE Control Statement” on page 113 for
details on syntax and parameters).
Note: The definition data set may contain SCRPOol, TAPEREQ, UNITATTR,
VOLATTR, and OPTion TITLE statements. Only OPTion TITLE and SCRPOol
statements are processed. If any other statement is encountered, an error message is
issued and the statement is ignored.
dataset.name
specifies the name of the data set containing scratch subpool parameters. If the
data set name includes a member name, dataset.name must be enclosed in
quotes. For example,
DATASET(‘YOUR.DSN(MEMBER)’)
VOLume
specifies the serial number of the DASD volume on which the data set resides. This
parameter is optional. Specify the VOLume parameter if the data set is not cataloged,
or if a data set on a volume other than the volume indicated by the catalog is to be
used.
Note: The volume specified must be a DASD volume.
volser
specifies the volume serial number for the definition data set.
SCRPDEF
DSN(dataset.name)
DATASET(dataset.name)
VOLume(volser) UNIT(unitname)
HOSTID( host-id
,
)
SCRPDEF