Chapter 4. Utility Functions 191
1st ed., 6/30/04 - 312579601
Cartridge Movement Statistics - Move Section of the Report
In the first section of the report, the Move section, the HSC provides two summary lines:
• The first summary line lists from 1 to 16 SMF system IDs found in the SMF records
input to the utility.
• The second summary line lists the SMF record type being reported, the total number
of SMF records, and the date (mm/dd/yy or yyyymmdd) and time (hh:mm:ss) of the
earliest and latest SMF record found matching the duration criteria.
The HSC SMF record type can be changed. When changed, the data extracted from
SMF represents the most recent SMF record type, and records with prior SMF record
types are ignored.
The duration criteria are specified in the Activities Report utility syntax as input via
the SLSIN parameters.
For the Move section of the Activities Report, every move type is reported under the
following headings:
Total
is the count of all operations for the move category listed found in the SMF input
matching the duration criteria.
This is calculated as the sum of the number of operations found in the SMF records
for the move category.
The value is reported as a count of moves and can range from 0 to 99,999,999,999
moves.
The major move categories are:
• all mounts (includes cleaning mounts)
• all dismounts (includes cleaning dismounts)
• all enters
• all ejects.
Subcategories for mount/dismounts are:
• scratch - same LSM
• scratch - diff LSM
• nonscratch - same LSM
• nonscratch - diff LSM.
Subcategories for enter/ejects are:
• ejects-same LSM
•ejects-diff LSM
• enters-same LSM
• enters-diff LSM.
Activities Report