6-4 Field Control Genius® Bus Interface Unit User’s Manual
October 1999 GFK-0825F
6
4. The Faults menu appears:
F1 First 16 Flts
F3 Previous Menu
F2 Last 16 Flts
5. Press F1 to display the first set of 16 faults (one fault at a time). For example:
Slot #1 Fault#01
< > exit
EXTRA I/O MODULE
Use F1 and F2 to
display another
fault
Fault
message
If there are no faults, the HHM displays the message:
No Faults
on the top line.
6. To display the last 16 faults (if any):
A. Press F4 (exit) to return to the screen shown at the top if this page.
B. Press F2 (last 16 faults).
Clearing Faults
If faults are present, pressing Clear here has no
effect. To clear faults from the Hand-held Monitor
you need to do the following:
1. Return to the HHM Main Menu.
2. Press F2 (Analyze).
3. Press F3 (Block/Bus Status).
4. Press the Clear key.
Clearing faults from the Hand-held Monitor does
not clear faults at the host PLC. To keep the entire
system in step and up-to-date, fault clearing should
be performed from the host PLC.
F3
F2
F 1 : H H M U T I L I T I E S
F 2 : A N A L Y Z E
F 4 : D E V I C E M E M O R Y
F 3 : C O N F I G U R A T I O N
R E F S * _ * OI
F L D P R 2 0 v * . *
N O F O R C E
n x t p r v a c t v b u s
F 1 : M O N I T O R B L O C K
F 2 : M N T R / C N T L R E F
F 3 : B L O C K / B U S S T S
F 4 : P U L S E T E S T