Cisco Systems IPS 7.1 Home Security System User Manual


  Open as PDF
of 1042
 
B-35
Cisco Intrusion Prevention System CLI Sensor Configuration Guide for IPS 7.1
OL-19892-01
Appendix B Signature Engines
Meta Engine
Table B-15 lists the parameters specific to the Meta engine.
Table B-15 Meta Engine Parameters
Parameter Description Value
component-list Specifies the Meta engine component:
edit—Edits an existing entry.
insert—Inserts a new entry into the list:
begin—Places the entry at the beginning of the
active list.
end—Places the entry at the end of the active
list.
inactive—Places the entry into the inactive list.
before—Places the entry before the specified
entry.
after—Places the entry after the specified entry.
move—Moves an entry in the list.
component-count—Specifies the number of times
component must fire before this component is
satisfied
component-sig-id—Specifies the signature ID of the
signature to match this component on.
component-subsig-id—Specifies the subsignature
ID of the signature to match this component on.
is-not-component—Specifies that the component is
a NOT component.
name1
true | false
component-list-in-order Specifies to fire the component list in order. true | false
all-components-required Specifies to use all components. true | false
all-not-components-required Specifies to use all of the NOT components. true | false
swap-attacker-victim Swaps the attacker and victim addresses and ports
(source and destination) in the alert message and in any
actions taken.
true| false
(default)
meta-reset-interval Specifies the time in seconds to reset the Meta signature. 0 to 3600
meta-key Specifies the storage type for the Meta signature:
Attacker address
Attacker and victim addresses
Attacker and victim addresses and ports
Victim address
Axxx
AxBx
AaBb
xxBx
unique-victim-ports Specifies the number of unique victims ports required
per Meta signature.
1 to 256