Adding, Editing, and Deleting Virtual Sensors
Step 12 Change the subinterface with the inline VLAN pairs or groups assigned to this virtual sensor. You must
have already subdivided any interfaces into VLAN pairs or groups.
sensor(config-ana-vir)# physical-interface GigabitEthernet2/0 subinterface-number
subinterface_number
Step 13 Verify the edited virtual sensor settings.
ssensor(config-ana-vir)# show settings
name: vs1
-----------------------------------------------
description: virtual sensor 1 default:
signature-definition: sig1 default: sig0
event-action-rules: rules1 default: rules0
anomaly-detection
-----------------------------------------------
anomaly-detection-name: ad1 default: ad0
operational-mode: learn default: detect
-----------------------------------------------
physical-interface (min: 0, max: 999999999, current: 2)
-----------------------------------------------
name: GigabitEthernet0/3
subinterface-number: 0 <defaulted>
-----------------------------------------------
inline-TCP-session-tracking-mode: interface-and-vlan default: virtual-sensor
-----------------------------------------------
logical-interface (min: 0, max: 999999999, current: 0)
-----------------------------------------------
-----------------------------------------------
-----------------------------------------------
sensor(config-ana-vir)#
Step 14 Delete a virtual sensor.
sensor(config-ana-vir)# exit
sensor(config-ana)# no virtual-sensor vs1
Step 15 Verify the deleted virtual sensor. Only the default virtual sensor, vs0, is present.
sensor(config-ana)# show settings
global-parameters
-----------------------------------------------
ip-logging
-----------------------------------------------
max-open-iplog-files: 20 <defaulted>
-----------------------------------------------
-----------------------------------------------
virtual-sensor (min: 1, max: 255, current: 2)
-----------------------------------------------
<protected entry>
name: vs0 <defaulted>
-----------------------------------------------
description: default virtual sensor <defaulted>
signature-definition: sig0 <protected>
event-action-rules: rules0 <protected>
anomaly-detection
-----------------------------------------------
anomaly-detection-name: ad0 <protected>
operational-mode: detect <defaulted>
-----------------------------------------------
physical-interface (min: 0, max: 999999999, current: 0)
-----------------------------------------------
-----------------------------------------------
logical-interface (min: 0, max: 999999999, current: 0)
-----------------------------------------------