Bosch Appliances 8-Dec Home Security System User Manual


 
88 | Accessories for Control Panels and Keypads | Interface Modules
Two Red LEDs Function
BUS RX Data bus receives data from control
panel
BUS TX Data bus transmits data to control
panel
Two Green LEDs Function
SER RX RS-232 receives data from serial de-
vice
SER TX RS-232 transmits data to serial device
Certifications and Approvals
Region Certification
Europe CE 89/336/EEC, EN55022: 1994 +A1: 1995
+A2: 1997 Class A, EN50130-4: 1995
+A1: 1998 +A2: 2003, EN60950-1:
2001, EN61000-3-2: 2000,
EN61000-3-3: 1995 +A1: 2001
Australia C-Tick
Installation/Configuration Notes
Compatibility Information
Applications and RS-232 Devices
United
States
RPS: Supported on all compatible control panels.
PC9000: Supported on all the following control panels:
D9412G, D7412G, D7212G, D9112,
D7412, and D7212.
Building Integra-
tion Software
(BIS):
Supported on the following SDI bus control
panels (version 6.3 and higher): D9412G,
D7412G, and D7212G.
China CMS 7000: Supported on DS7400Xi Control Panels (op-
tion bus) set at Mode 18 (version 3.09 or
higher).
All Printers: Supported on option bus control panels.
SDI Bus Control Panels (version 6.0 or higher)
United
States
D7212G, D7412G, and D9412G
D7212, D7412, and D9412
D9112
Option Bus Control Panels
Europe
DS7400Xi (version 2.02 or higher)
DS7220 and DS7240
Australia
CC7420-A
United
States
D4412 and D6412
The DX4010i RS-232 Serial Interface Module replaces the
following modules:
United States D9133 Serial In-
terface Module
For use with BIS, PC9000, or other
third party applications on SDI bus con-
trol panels.
D9133DC Serial
Interface Module
For use with RPS or other third party
applications on SDI bus control panels.
D9533 RS-232
Serial Interface
Module
For use with RPS, CMS 7000*, or print-
ers on option bus control panels
Europe, Unit-
ed States, and
China
DX4010 RS-232
Serial Interface
Module
For use with RPS, CMS 7000*, or print-
ers on option bus control panels.
*CMS 7000 is available in China only.
Technical Specifications
Environmental Considerations
Operating Temperature: 0°C to +50°C
(+32°F to +122°F)
Relative Humidity: 5% to 85% at +30°C (+86°F) non-condensing
Power Requirements
Current (Maximum): 50 mA nominal, 55 mA with LED
Voltage (Operating): 8 VDC to 14 VDC
Ordering Information
DX4010i RS‑232 Serial Interface Module
Locally connects compatible control panels
and approved applications or other RS-232
devices.
DX4010i
Bosch Security Systems B.V. www.boschsecurity.com