Bosch Appliances 8-Dec Home Security System User Manual


 
LSN Peripherals | LSN Magnetic Contacts | 357
MSA-LSN C Surface-Mount
Magnetic Contact
Features
LSN surface-mount magnetic contact
VdS class C
Tamper switch
Parallel or head-on surface mounting
LSN perimeter protection
Magnetic contacts are used for tear-off surveillance of
doors and windows.
Certifications and Approvals
Region Certification
Europe CE MSE/MSA-LSN B/C
Germany VdS G 104006, C MSE/MSA-LSN C
Coun-
try
Certification MSA-LSN C
DE VdS G 104006, C
Installation/Configuration Notes
Installation notes
Head-on or parallel surface mounting.
The surface mounting version is implemented via the
AG4 surface mounting housing and enables installation
on ferromagnetic materials.
1 Contact
2 Magnet
3 AG4 surface mounting housing
4 Plastic part
5 Magnet offset in the axial direction
6 Warning! The adjustment mark must point to the magnet.
Connecting LSN contacts
Each LSN contact is a physical LSN element (1 out of
127 possible per loop).
The length of LSN contact connection cables must be
included when planning the total line length of the LSN
loop, as LSN technology is incorporated in these
detectors.
Passive coupling elements for joining the connection
cables to the installation cable must be placed as close
as possible to the LSN contacts. The 1 m connection
cable with 2 m LSN cable length is included in the
calculation of the LSN cable length (LSN is carried into
the contacts and back out again).
Connector boxes (optional) are classified as installation
material.
Testing LSN contacts
Reed switch and microswitch functions can be checked
before installation by a high-Ohm multimeter or
continuity checker (for diode paths).
The resistance values are approximate values; a large
change in resistance is significant here.
1 Detector
2 High-Ohm multimeter
Contact open: approx. 3 megaohm
Contact closed: approx. 1 megaohm
Note Only the intrusion contact can be checked in
this way. The tamper switch of the Class C
magnetic contact can be checked by the LSN
control panel or with the LSN testing device
(software version 3.x onward).
www.boschsecurity.com Bosch Security Systems B.V.
6