Bosch Appliances 8-Dec Home Security System User Manual


 
Detectors and Accessories | Motion PIR | 153
DS308EA Quad PIR
Detector with Anti-mask
Features
Anti-mask with spray detect
Quad element design
Microprocessor controlled self-test supervision
systems
Q-map signal processing
Field replaceable pointable mirrored optics
Temperature compensation
Motion Monitor
The wall mount DS308EA Quad PIR Detector uses Q-map
signal processing and a four-element (Quad), dual opposed
sensor design to provide excellent catch performance with
freedom from false alarms. The Anti-masking feature can
detect a cover-up or an intentional or accidental blocking
by sending a trouble signal to the panel. Test features,
including Motion Monitor, provide coverage integrity.
Functions
Anti-mask with Spray Detect
PIR Anti-mask feature detects objects placed over the cover
of the detector or sprayed on the lens area. Anti-mask
sensitivity is selectable, and anti-mask activation can be
delayed to reduce false alarms.
Q-map Signal Processing
Analyzes the signals from each channel to eliminate false
alarms. The horizontally opposed signals must match with
specific timing, amplitude, and signatures to cause an
alarm. Q-map adjusts for small targets that cause signals in
one channel but not the adjacent, opposing channel. This
reduces false alarms from small targets such as rodents,
while maintaining catch performance of human-sized
targets.
Test Features
LED flashes to indicate a trouble condition. Dual
channel internal noise voltage test pins use standard
analog meter to provide precise pattern location and
background disturbance evaluation.
Remote Walk Test Control: The walk test LED can be
activated remotely through a control panel command.
Temperature Compensation
Automatically monitors the ambient temperature and
adjusts the Signal processing to maintain proper catch
performance at critical temperature ranges.
Alarm Memory
Provides indication of stored alarms. Controlled by a
switched voltage from the control panel.
Certifications and Approvals
Region Certification
Europe CE 89/336/EEC, EN55022: 1998,
EN50130-4: 1995 +A1: 1998 +A2: 2003,
EN61000-4-2: 1995 +A1: 1998 +A2:
2001, EN61000-4-3: 2002 +A1: 2002,
EN61000-4-4: 1995 +A1: 2000 +A2:
2001, EN61000-4-5: 1995 +A1: 2001,
EN61000-4-6: 1996 +A1: 2001
Poland CNBOP DS308EA only: 92/03
USA UL DS308EA only: ANSR: Intrusion detection
Units (UL639)
Italy IMQ DS308EA-ITA: U0616
China CCC DS308EA-CHI: 2004031901000034
Sweden INTYG DS308EA only: Nr04-754
France AFNOR NF, A2P
Europe DS308EA complies with EN50131-1 grade 3
www.boschsecurity.com Bosch Security Systems B.V.