160 | Detectors and Accessories | Motion PIR
Top View
Standard Broad Coverage: 10 m x 10 m (35 ft x 35 ft)
Side View
Standard Broad Coverage: 10 m x 10 m (35 ft x 35 ft)
Top View
Optional Barrier Coverage: 10 m x 3 m (35 ft x 10 ft)
SideView
Optional Barrier Coverage: 10 m x 3 m (35 ft x 10 ft)
Top View
Optional Long Range Coverage: 21 m x 3 m (70 ft x 10 ft)
Side View
Optional Long Range Coverage: 21 m x 3 m (70 ft x 10 ft)
Technical Specifications
Enclosure Design
Dimensions: 10.8 cm x 7 cm x 4.6 cm
(4.25 in. x 2.75 in. x 1.8 in.)
Environmental Considerations
Temperature
(Operating):
-29°C to +49°C (-20°F to +120°F)
For UL Listed Applications, 0°C to + 49°C (+32°F to
+120°F)
Radio Frequency
Interference
(RFI) Immunity:
No alarm or setup on critical frequencies in the range from
26 MHz to 950 MHz at 50 V/m.
Mounting
Height (recommended): 2 m to 2.6 m (6.5 ft to 8.5 ft)
Location: Surface or corner mount.
Ceiling mount with the appropriate mounting
bracket.
Internal Pointability: Coverage is adjustable ±10° horizontally, +1°
to -18° vertically.
Outputs
Alarm: Signals through the multiplex bus
Tamper: A tamper condition is signaled through the multiplex bus and
displays at the keypads.
Power Requirements
Current Draw (two-
wire):
LED off: <0.4 mA draw on MUX bus
LED on: 2 mA draw on MUX bus
Current Draw (four-
wire):
LED off: <0.4 mA draw on MUX bus
0 mA draw on Aux. power
LED on: <0.4 mA draw on MUX bus
3 mA draw on Aux. power
Input (Voltage): Connects directly to the multiplex (MUX) bus of the
control panel and optionally to an auxiliary 12 VDC
source
Standby Power: There is no internal standby battery. Connect to DC
power sources capable of supplying standby power if
primary power fails. For each hour of standby time
needed, 0.4 mAh are required. For UL Listed Require-
ments, four hours (1.4 mAh) minimum are required.
Bosch Security Systems B.V. www.boschsecurity.com