Bosch Appliances 8-Dec Home Security System User Manual


 
Detectors and Accessories | Request-to-Exit | 213
DS160 Series High
Performance
Request‑to‑exit Detectors
Features
Door monitor with sounder alert
Sequential Logic Input (SLI)
Internal vertical pointability
Wrap-around coverage pattern with precise pattern
control
Up to 64 second adjustable latch time
Selectable relay trigger mode
Selectable fail-safe or fail-secure modes
Adjustable sounder volume
Activation LED
The DS160 Series consists of the DS160 Detector (light
gray) and the DS161 Detector (black) specifically designed
for Request-to-exit (REX) applications. With features such
as timers, door monitor with sounder alert, and pointable
coverage, the DS160 and DS161 have the flexibility to meet
the most stringent REX requirements. The exclusive
Sequential Logic Input (SLI) provides added security that is
not offered in any other REX device.
Functions
Sequential Logic Input (SLI)
The SLI terminal allows connection of a second device to
require sequential detection. This eliminates the possibility
that an object that is slid through the door or underneath
the door will activate the detector. This input can also be
used to lock the sensor if motion is present outside the
premises.
Door Monitor
The sensor can monitor a door contact to allow special
control of the internal relay. For example, if the door is
opened within the relay time period, the sensor can be
programmed to halt the timer. If the door is not opened
within a specific time period, the relay can be programmed
to deactivate.
Sounder Alert
An integrated sounder can be programmed to activate if the
door is left open too long. The sounder volume is fully
adjustable to 85 dB.
Keycard Input
The keycard input allows the sensor relay to be controlled
from an external source, such as an access control system
or card reader.
Certifications and Approvals
Region Certification
Europe CE 89/336/EEC, EN55022: 1998 +A1: 2000
+A2: 2003, EN50130-4: 1996 +A1: 1998
+A2: 2003, EN61000-4-2: 1995 +A1:
1998 +A2: 2001, EN61000-4-3: 2002
+A1: 2003, EN61000-4-4: 1995 +A1:
2000 +A2: 2001, EN61000-4-5: 1995
+A1: 2001, EN61000-4-6: 1996 +A1:
2001 +A2: 2001, EN61000-4-11:1994
+A1: 2001, EN60950-1: 2001
Poland CNBOP DS160
USA UL ALVY: Access Control Systems Units
(UL294)
Europe Complies with EN50131‑1 Grade 2
Installation/Configuration Notes
Front View
Mounted on wall above door and mounted on ceiling .75 m
(2.5 ft) in front of the door.
www.boschsecurity.com Bosch Security Systems B.V.
5