262 | Detectors and Accessories | Magnetic Contacts Recessed Mount
MS-LZ Flush-Mount
Magnetic Contact
Features
▶
Conventional flush-mount magnetic contact
▶
VdS class B
▶
Head-on or parallel flush mounting
▶
Conventional perimeter protection
Conventional magnetic contacts are used for opening
surveillance of windows and doors.
Certifications and Approvals
Region Certification
Europe CE MS-LZ
Germany VdS G 191568, B MS/MSA-LZ
Installation/Configuration Notes
Installation notes
•
Installation can be parallel or head-on.
•
Head-on installation in ferromagnetic materials is
possible with the EG1 flush-mount housing.
•
The magnet should be fixed in the bore.
•
For VdS applications, the MS-LZ flush-mount magnetic
contact cannot be used in ferromagnetic materials.
1 Contact
2 Magnet
Parts Included
Type Quant. Component
MS-LZ 1 Recessed mount magnetic contacts
incl. 6 m cable
Technical Specifications
Type of installation Flush, parallel or head-on
Contact Normally open contact
Permissible contact load ≤ 5 Watt
Switching current 10 to 100 mA
Switching voltage max. ≤ 110 V_
Switch tolerance
≥ 10
7
Magnet AlNiCo 500
Switch dimensions Ø 8 mm x 30 mm
Magnet dimensions Ø 8 mm x 30 mm
Axial installation distance ≤ 15 mm
Temperature range -25 °C to +70 °C
Connection cable 6 m, LiYY 4 x 0.14 mm
Protection category IP68
Bosch Security Systems B.V. www.boschsecurity.com