Bosch Appliances 8-Dec Home Security System User Manual


 
LSN Peripherals | LSN Expansion Modules | 375
Installation
When installing the KR 100 LSN, the factory-installed solder
distributors must be removed. A maximum of four
KR 100 LSNs can be installed per NVK 100 LSN. One solder
distributor is supplied per two KR 100 LSNs.
Coupler power supply
The LSN part of all LSN elements (couplers and detectors)
is supplied with power via the control panel's 2-wire LSN
line.
All LSN couplers are designed to loop through the power
supply (+V, -V) of subsequent couplers.
The maximum cable length of the separate power supply
(+V, -V) depends on the power intake of the couplers to be
supplied and their peripherals, if not powered by an
external source.
Cable lengths
Cable length per primary line (PL) or control lines
Maximum length unshielded cable – 10 m
Maximum length shielded cable – 500 m
The primary cables, control cables and contact cables from
the NVK 100 may not exceed a total of 500 m per network
processing implementer (NVU).
Optional KR 100 LSN relay module for LSN expanders
The KR 100 LSN relay module for LSN expanders is intended
for use in the NNK 110 LSN and NVK 100 LSN.
The KR 100 LSN is installed if the high power requirement
means the connected control elements cannot be
controlled directly from the LSN couplers, or in order to
enable zero-potential switching.
Up to four KR 100 LSNs can be installed per NNK 110 LSN
or NVK 100 LSN. One solder distributor is supplied per two
KR 100 LSNs.
Parts Included
Type Qty. Component
NVK 100 LSN 1 Coupler
Technical Specifications
Operating voltage
LSN part
+10 V to +33 V
Other expansion module func-
tions
+8 V to +30 V
Current consumption
LSN part 3.5 mA
Other expansion module functions
Idle:
Max. 50 mA at +8 V
Max. 40 mA at +12 V
Max. 30 mA at +30 V
Full load:
Max. 315 mA at +8 V
Max. 230 mA at +12 V
Max. 105 mA at +30 V
Connection options DC primary lines
Primary lines 1 to 4
as hold-up, intrusion, tamper, or clo-
sure zone
Primary line 5
Block-type lock/or coded arming de-
vice
Primary line 6
as hold-up, intrusion, tamper, or clo-
sure zone or for coded arming device
End-of-line resistors
Primary lines 1 to 4
R= 12.1 kilohm 1%
Primary line 5
R = 12.1 kilohm 1% (armed)
R = 12.1 kilohm // 3.92 kilohm
(disarmed)
Primary line 6
(Hold-up, intrusion, tamper,
not with NZ 300)
R = 12.1 kilohm +1%
Primary line 6
(Log. switching equipment)
R = 12.1 kilohm +1%
Invalid coded arming device
12K1 II 3K92 +1%
Valid coded arming device
Monitoring tolerance at
PL 1 to 4 (PL 6 if necessary)
40% of end-of-line resistor (EOL)
Response time PL 1 to 6 < 200 ms
Control outputs
Max. current
20 mA
Max. voltage
8 V
Max. line resistance
2 x 10 Ohm
Short-circuit stability
2 s
Block-type lock magnet
Max. current
60 mA
Max. voltage
12 V
Max. line resistance
2 x 5 Ohm
Short-circuit stability
2 s
Ambient climate DIN 40040 R14
Permitted ambient temperature 0 °C to +55 °C
Housing
Base
Plastic
Cover
Plastic
Color
RAL 9002 grayish white
Weight Approx. 450 g
Dimensions (H x W x D) 215 x 160 x 35.5 mm
Protection type IP 30
Environmental class II (VdS 2110)
KR 100 optional
Reel
Response voltage
> 7 V
Fall-off voltage
< 1 V
Reel voltage
Max. 14.3 V
Contacts
www.boschsecurity.com Bosch Security Systems B.V.