Bosch Appliances 8-Dec Home Security System User Manual


 
Accessories for Control Panels and Keypads | Expansion Modules | 77
DS7457iE Single Zone
Input Module
Features
Power-limited and supervised input zones
Compact enough to fit within most backboxes and
enclosures
Address settings through DIP switches
The DS7457iE is a Single Zone Input Module designed for
intrusion applications. It has a dual-resistor supervised
input zone for connecting normally-open (NO) or normally-
closed (NC) contacts. The DS7457iE controls the contacts
using 22kΩ+47kΩ resistors for serial dual end-of-line (EOL)
wiring. Each DS7457iE operates with compatible multiplex
expansion modules and occupies one multiplex zone
address on the system.
Certifications and Approvals
Region Certification
Europe CE 89/336/EEC, EN55022: 1998,
EN50130-4: 1995, EN60950: 2000,
EN61000-3-2, EN61000-3-3,
EN61000-4-2, EN61000-4-3,
EN61000-4-4, EN61000-4-5,
EN61000-4-6, EN61000-4-11
Installation/Configuration Notes
Compatibility Information
Control Panels DS7400Xi Control Panel
Multiplex Modules DS7430 Multiplex Expansion Module
DS7436 Multiplex Expansion Module
Wiring Considerations
Refer to the intended control panel’s installation guide for
multiplex wiring requirements. The recommended wiring to
the control panel is four-wire 0.8 mm cable. Do not use
shielded or twisted pair cable.
Note The length of the wiring connected to the
protection loop (and tamper loop) must be
less than 76 m.
Technical Specifications
Environmental Considerations
Temperature (Operating): 0°C to +49°C
Power Requirements
Current Draw: 0.5 mA Standby and alarm
Voltage (Operating): 8 VDC peak (minimum)
Circuit Parameters
Zone Response Time: 400 ms
Ordering Information
DS7457iE Single Zone Input Module
Designed for intrusion applications. Includes a
dual-resistor supervised input zone for con-
necting normally-open (NO) or normally-
closed (NC) contacts.
DS7457iE
www.boschsecurity.com Bosch Security Systems B.V.
2