Bosch Appliances 8-Dec Home Security System User Manual


 
Accessories for Control Panels and Keypads | Power Supplies and Batteries | 109
The LSN a/b line current, max. 100 mA, is supplied by
the control panel.
The NEV 300 LSN can be operated directly next to the
control panel (centralized) or remotely (decentralized).
Installation cable for LSN technology: J-Y(St)Y
Shielding (drain wire) must be routed to the ground
connectors for each LSN line. There must be no
connection between the housing potential and the LSN
cable shielding.
28 V voltage converter (optional)
The basic voltage of the power supply is 12 V. If the voltage
drop is too high due to cable length, a 28 V voltage converter
(optional) can be plugged into the connector board. 28 V
for 2 x +V/0 V and 1 x user output as needed. Power intake
for the three outputs totals 500 mA.
TRN panel relay module (optional)
Panel module with 2 relays for zero potential outputs, one
switching contact per relay. Up to 2 units can be plugged
into the connector board.
Parts Included
Type Qty. Component
NEV 300 LSN 1 Housing, control assembly, connector
board, and cable set without batteries, pan-
ic button incl. adhesive seal
Technical Specifications
Power supply
Protection class
I (DIN VDE 0106 Part 1)
Mains voltage
230 V (+10% to -15%)
Mains frequency
50 Hz
LSN technology
Operating voltage
+15 V to +31 V
Current consumption
Max. 3.85 mA
Control unit
Battery charge voltage
From 0 °C to 50 °C according to the
battery charge discharge characteris-
tics (factory setting: 13.8 V at 20 °C)
Battery charge
Bk/20 at 34 Ah = 1.7 A
Battery capacity
12 V/2 x 17 Ah
Output voltage
Corresponds to battery charge volt-
age
Output current (battery
charge current + user cur-
rent)
Max. 4.0 A
Current available on connector board
+V/0 V and external users
Max. 2.3 A
With bridging time of 60 hrs
< 600 mA
With bridging time of 30 hrs
< 1.2 A
Current available at 28 V from
connector board (+V/0 V and
ext. users)
500 mA in total
Voltage control protection
Protection for control
> 16 V
Voltage surge protection
> 5.5 A
Monitoring
Network fault
< 130 V
Battery fault
(discharge battery)
≤ 10.5 V
Total battery discharge pro-
tector (TES)
< 10 V
Switch outputs (C points)
Principle
Open collector
(short-circuit resistant)
Max. voltage
10 V to 30 V
Maximum current
300 mA
28 V voltage converter (optional)
Load current Max. 500 mA in total
Electromagnetic compatibility (EMC)
Interference immunity
DIN EN 50130-4
Interference emissions
DIN EN 50081-1
Environmental conditions
Ambient temperature
(in operation)
-5 °C to +45 °C
Storage and transport tem-
perature
- 25 °C to + 70 °C
Environmental class
II (VdS 2110)
Housing protection category IP 30
Humidity + 40 °C, 93% rel. humidity
Housing
Dimensions (H x W x D)
460 x 380 x 97 mm
Color
Light gray/RAL 7035
Weight (without batteries/with bat-
teries)
2 kg/15 kg
Ordering Information
NEV 300 LSN power supply
For additional power supply to LSN control
panels, housing incl. 12 V/4.0 A power supply
unit, a maximum of two 12 V/17 Ah batteries
can be used
4998111983
Accessories
TRN panel relay module
With 2 relays, one switching contact per relay
for zero potential outputs
ICP-TRN
ERWE 10 voltage converter
For connecting NBK 100 LSN, NTK 100 LSN,
NSB 100 LSN, MSS 401, ERT 100,
FK 100 LSN, can be plugged into the
NEV 300 LSN connector board
ERWE 10
www.boschsecurity.com Bosch Security Systems B.V.
2