Bosch Appliances 8-Dec Home Security System User Manual


 
60 | Control Panels, Control Centers, and Keypads | UEZ 2000
Message display and operation
The integrated operating unit (ADT) or a remote operating
panel can be used to process incoming messages and
operate the system.
Saving messages
A log printer can be integrated to record messages. Up to
1000 events can be stored in an event database.
System loop technology (SRT)
Up to 6 control panels in one SRT loop (UEZ 2000 and/
or UEZ 2000)
Central or decentralized assignment as required
Cost-effective networking using standard cabling (4-
wire) up to 1000 m
Greater coverage via modem or fiber optic cable
High level of operating reliability through fault-tolerant
operation in the event of a line short-circuit or
interruption
Malfunction message reported to all systems to aid in
malfunction localization
One or more transmitters can be integrated into the
cluster as required
All information is available at each control panel
Complete simultaneous operation is possible and
permitted on all control panels
Up to 508 detector zones
Up to 2032 LSN elements
Built-in operating panel and printer (optional) per
control panel
Up to 4 remote BE 1000 operating panels per control
panel
Encrypted data transmission in the SRT loop
Up to 48 LSN loops or 96 stubs or a combination of both
with the UEZ 2000 LSN SRT
Additional function with the UEZ 2000 LSN
The UEZ 2000 LSN can also be equipped with an additional
LVM 100. This increases the connection potential to 8 loop
or 16 stub lines and/or a max. of 508 connectable LSN
elements.
Certifications and Approvals
Region Certification
Europe CE UEZ 2000 LSN
UEZ 2000 LSN A2
Germany VdS-S S 184507, B NMZ 300 H
S 196602, B NMZ 1000 B
S 196001, C NMZ 1000 C
S 17370, C NMZ 300
VdS G 197009, C UEZ 2000 N
Installation/Configuration Notes
One-man test
Automatic service request in the event of detector
contamination
127 detector zones
99 detectors per detector zone (not VdS)
32 detector area
5 fixed and 19 variable control panel C points
Internal and external expansion options
Components Number Short description
Internal extension
SEMO1 1 Module with 2 serial interfaces and SEZU
(encrypted data transmission)
AT 2000 1 Dial-up modem for transmitting informa-
tion via the telephone network to a moni-
toring station and/or TeleService
DIP 1 Switching an internal program on or off
from multiple independent points
NRK-N 2 For 230 V switching outputs; C point ac-
tivation
TRSP 1 Integration of up to 5 x TRN
SIV 1 For additional monitored protection of
users connected to the UEZ 2000 LSN
LSA+ 1 Additional connection strip
ASE 1 For connecting 2 x 2 BES in parallel, can
be plugged into AVM 100
TRN 6 For zero-potential outputs of control pan-
el functions; can be plugged into AVM 100
RTP 6 For zero-potential outputs of 4 control
panel functions each; can be plugged into
AVM 100
SM 20 5 Interface module for 20 mA interface; for
connecting a printer, UGM 2020, RUBIN
2020NT or BoVis NT
SM24 3 Interface module for V.24 interface; for
connecting UGM 2020, RUBIN 2020NT,
Bovis NT or SRT
SM 485 1 Interface module for RS-485 interface,
for connecting 4 x BE 1000
Printer 1 Message logging
ATE 100 LSN 1 Parallel display of 32 detector zones (can
be installed in operating panel)
Key switch 8
or 1
and 6
With 2 activation settings
With 3 switch setting options (1-0-2) in
the operating panel
With 2 switch settings
12 V/10 Ah battery 2 Uninterrupted power supply (UPS) to the
system
External extension
External signaling
device
8 Up to 8 independently activated BESs can
be connected via ASE and NSB 100
ATBL 8 For connecting remote display panels,
each with 64 outputs
Transmission equip-
ment (VdS)
1 For transmitting emergency call alarms to
a receiving center
SD 1 Connection is made at the AVM 100
UEV 1000 1 For additional energy requirements; con-
tains one 12 V/5.4 A power supply unit
and 2 12 V/40 Ah batteries