Bosch Appliances 8-Dec Home Security System User Manual


 
LSN Peripherals | LSN Magnetic Contacts | 351
MSE-LSN B Built-In
Magnetic Contact
Features
LSN flush-mount magnetic contact
VdS class B
Head-on or parallel flush mounting
LSN perimeter protection
Magnetic contacts are used for tear-off surveillance of
doors and windows.
Certifications and Approvals
Region Certification
Europe CE MSE/MSA-LSN B/C
Germany VdS G 104502, B MSE/MSA-LSN B
Installation/Configuration Notes
Installation notes
Head-on or parallel flush mounting.
The magnet should be fixed in the bore.
Head-on installation in ferromagnetic materials is
possible with the EG1 flush-mount housing.
1 Contact
2 Magnet
Connecting LSN contacts
Each LSN contact is a physical LSN element (1 out of
127 possible per loop).
The length of LSN contact connection cables must be
included when planning the total line length of the LSN
loop, as LSN technology is incorporated in these
detectors.
Passive coupling elements for joining the connection
cables to the installation cable must be placed as close
as possible to the LSN contacts. The 1 m connection
cable with 2 m LSN cable length is included in the
calculation of the LSN cable length (LSN is carried into
the contacts and back out again).
Connector boxes (optional) are classified as installation
material.
Testing LSN contacts
Reed switch and microswitch functions can be checked
before installation by a high-Ohm multimeter or
continuity checker (for diode paths).
The resistance values are approximate values; a large
change in resistance is significant here.
1 Detector
2 High-Ohm multimeter
Contact open: approx. 3 megaohm
Contact closed: approx. 1 megaohm
Note Only the intrusion contact can be checked in
this way. The tamper switch of the Class C
magnetic contact can be checked by the LSN
control panel or with the LSN testing device
(software version 3.x onward).
Parts Included
Type Qty. Component
MSE-LSN B 1 Built-in magnetic contact
incl. 4 m cable
Technical Specifications
Type of installation Flush, head-on or parallel
Operating voltage Max. 33 V_
Reed contacts Normally open contact
Switch tolerance
≥ 10
7
Magnet AlNiCo 500
Switch dimension: Ø 8 mm x 30 mm
Magnet dimension: Ø 8 mm x 30 mm
Axial installation distance: ≤ 15 mm
Installation distance with EG1 2 to 6 mm
Temperature range -25 °C to 70 °C
Connection cable: 4 m, LiY(St) Y 4 x 0.14 mm
with screen, exterior Ø 3.2 mm
www.boschsecurity.com Bosch Security Systems B.V.
6