Bosch Appliances 8-Dec Home Security System User Manual


 
34 | Control Panels, Control Centers, and Keypads | Solution Series
CP516W LED Codepad
Features
Single button arming of alarm system
Fire, medical and panic alarms
Stylish and modern design
Clear and easy to use
Backlit buttons for illuminated operation during day or
night
The CP516W is a 16 zone LED codepad, with protective
door, that is compatible with the Solution 16 alarm panel.
The CP516W has a user-friendly design. It uses a
combination of numbers and words to display the alarm
system condition and creates easy operation for users.
The codepad will notify you when a zone is unsealed, when
there has been an alarm and in which zone the alarm has
occurred.
Also included as a standard feature are a number of single
button functions that will allow a user to perform various
system operations by simply holding down a button for two
seconds. For example, holding the AWAY button will arm the
system, holding the 1 button will test the sirens and holding
the 3 button will test the strobe lights.
System Overview
If programmed to do so Fire, Panic and Medical alarms can
be easily triggered from any codepad by pressing the
outside buttons at the same time.
Arming Methods
Method #1: Enter the User code followed by the AWAY
button. The AWAY indicator will display.
Method #2: Hold down the AWAY button for two
seconds. The AWAY indicator will display.
For further details on codepad operation please see the
Solution panels listed in the Install and Configuration
Notes, and then refer to the appropriate Operator Guide for
the panel.
To disarm the system in AWAY mode, enter the user code
followed by the AWAY button.
Installation/Configuration Notes
Compatibility Information
Control Panels Solution 16
Mounting Considerations
The CP516W can be surface mounted indoors through two
to four screws.
Technical Specifications
Enclosure Design
Dimensions: 7.2 cm x 12.7 cm x 2.3 cm
(2.8 in. x 5 in. x 1 in.)
Environmental Considerations
Storage Temperature: +0°C to +50°C (+32°F to 122°F)
Relative Humidity: 20% to 90% (non-condensing)
Power Requirements
Operating Voltage: 11 VDC to 14VDC
Current Draw: 50 mA (maximum)
Radio Frequency
Interference (RFI) Immunity:
Complies with AS/NZS3548
Ordering Information
CP516W LED Codepad
Shows 16 zones and provides a protective
door. Compatible with the Solution 16 Alarm
Panel.
CP516W
Bosch Security Systems B.V. www.boschsecurity.com
1