Bosch Appliances 8-Dec Home Security System User Manual


 
280 | Detectors and Accessories | Magnetic Contacts Surface Mount
MK 48 SZ surface-mount
magnetic contact
Features
Conventional surface-mount magnetic contact
VdS class C
Tamper switch
Parallel installation, surface mounted and flush
mounted
Conventional perimeter protection
Can be used in the SPE blocking element (installed on
frames/doors) according to VdS Class C
Conventional magnet contacts are used for tear-off
surveillance of windows and doors.
Certifications and Approvals
Region Certification
Europe CE MK 48 S Z
Germany VdS G 191019, C MK 48 S Z
Installation/Configuration Notes
Installation notes
Magnetic contact and magnet are mounted parallel to
each other using the surface-mount or flush-mount
housing.
When inserting the contact housing, please ensure that
the labeling stud on the face is pointing toward the
magnet, regardless of the type of installation.
The distance between the contact and the magnet must
be between 7 mm and 16 mm; 12 mm is preferred.
Installation in ferromagnetic materials is not
permissible.
Installation can be completed with or without a plastic
sleeve. If no plastic sleeve is used, the components
should be fixed in the bores.
1 Contact
2 Magnet
3 Axial installation offset
Distances diagram
1 Extraction
2 Proximity switch part
3 Secure area
4 Tolerance
5 Tamper area
Parts Included
Type Qty. Components
MK 48 S Z 1 Surface-mount magnetic contact
Magnet (8 x 8 x 40 mm) incl. 2x surface
mounting housing,
2 caps with 4 bases
Bosch Security Systems B.V. www.boschsecurity.com
5