Bosch Appliances 8-Dec Home Security System User Manual


 
Wireless Local Security Network (wLSN) | wLSN Accessories | 459
Mounting Considerations
The required region-specific transformers have 1.8 m (6 ft)
cords. Position the docking units near a wall outlet in order
to plug in the transformer.
Note Refer to the wLSN Installation Tool Installation
Instructions (P/N: F01U008748) for
instructions on connecting the transformers to
the docking stations.
Mount the wall-mount docking station to an interior wall
and/or place the desktop docking station on a flat surface.
The docking stations must be protected from weather
elements such as rain or snow and from accidental
exposure to spills or leaks.
Parts Included
Quant. Component
1 Installation tool
1
Transformer (region specific)
1
2 Docking stations (wall and desktop)
3 AAA (NiMH) batteries (P/N: 16556)
1 Hardware pack
1 Literature pack
1
Each installation tool is supplied with a region-specific
transformer designed to be wired to either of the docking
stations and to plug into the local electrical outlet. Refer to
the following for transformer illustrations:
European transformer (A) supplied with ISW-BIT1-HAX
United Kingdom transformer (B) supplied with ISW-BIT1-HBX
United States transformer (C) supplied with ISW-BIT1-HCX
Technical Specifications
Environmental Considerations
Environment: Indoor, dry
EN50131-1: Environmental Class II
Relative Humidity: Up to 95%, non-condensing
Temperature (operating): -10°C to +55°C (+14°F to +131°F)
Mechanical Properties
Color: Off-white
Dimensions (H x W x D): 12.6 cm x 7.5 cm x 4.5 cm
(5.0 in. x 3.0 in. x 1.8 in.)
Power Requirements
Battery Power
Battery Life: Up to 50 hr of continuous use on a single
charge.
Battery Requirements: Three AAA nickel-metal hydride (NiMH) re-
chargeable batteries
Recommended Replace-
ments:
SANYO® HR-AAAU
Recharge Time: Requires 7 hr to recharge fully depleted bat-
teries
External Power Supply (Docking Module)
Voltage (supply): 6 VDC to 14 VDC
Reception Characteristics
Frequency: European Security Band
868 MHz to 869 MHz
Transformers
All Transformer Models
Current (output): 0.33 A
Power: 8 W
Voltage (output): with load: 9.0 VDC ± 5%
ISW-BIT1-HAX (United Kingdom Transformer)
Frequency: 50 Hz
Voltage (input): 230 VAC to 240 VAC
Voltage (output): without load: 15.0 VDC ± 5%
www.boschsecurity.com Bosch Security Systems B.V.