Bosch Appliances 8-Dec Home Security System User Manual


 
LSN Peripherals | LSN Magnetic Contacts | 365
SKI 100 LSN Bolt Contact
Features
Bolt contact in LSN technology
For connecting to an LSN intrusion control panel
VdS class C
LSN perimeter protection
Bolt contacts are used for monitoring the closure of doors.
Certifications and Approvals
Region Certification
Europe CE SKI 100 LSN
Germany VdS G 101010, C SKI 100 LSN
Installation/Configuration Notes
Installation notes
Installation is carried out in the door bolt with the bolt
contact being activated by the tongue of the lock. It
should be kept in mind that only the second turn of the
key in the lock actually activates the contact. To make
any necessary adjustments, the bolt contact's operating
spring lever can be bent.
When installing in fire protection doors, please ensure
that no mechanical changes, except for the fastener
bores, are carried out on the door frames.
Connecting LSN contacts
Each LSN contact is a physical LSN element (1 out of
127 possible per loop).
The length of LSN contact connection cables must be
included when planning the total line length of the LSN
loop, as LSN technology is incorporated in these
detectors.
Passive coupling elements for joining the connection
cables to the installation cable must be placed as close
as possible to the LSN contacts. The 1 m connection
cable with 2 m LSN cable length is included in the
calculation of the LSN cable length (LSN is carried into
the contacts and back out again).
Connector boxes (optional) are classified as installation
material.
Testing LSN contacts
Reed switch and microswitch functions can be checked
before installation by a high-Ohm multimeter or
continuity checker (for diode paths).
The resistance values are approximate values; a large
change in resistance is significant here.
1 Detector
2 High-Ohm multimeter
Contact open: approx. 3 megaohm
Contact closed: approx. 1 megaohm
Note Only the intrusion contact can be checked in
this way. The tamper switch of the Class C
magnetic contact can be checked by the LSN
control panel or with the LSN testing device
(software version 3.x onward).
Parts Included
Type Qty. Component
SKI 100 LSN 1 Bolt contact for interior doors, without ca-
ble
Technical Specifications
Type of installation Flush
LSN operating voltage 15 V to 33 V
Current consumption 0.4 mA
VdS environmental class II
Protection category IP 54
Permissible
ambient temperature
-25 °C to +55 °C
Housing
Material
Steel plate
Color
Gray
Dimensions (H x W x D)
Without operating lever
37 x 10 x 19 mm
With operating lever
74 x 10 x 19 mm
Connection cable
None
www.boschsecurity.com Bosch Security Systems B.V.
6