Bosch Appliances 8-Dec Home Security System User Manual


 
Accessories for Control Panels and Keypads | Interface Modules | 85
Functions
Communication Formats
ADT-SIA
BFSK (2300Hz ACK Tone or 1400Hz ACK Tone)
DTMF (Contact ID, High Speed and 4/2 Express)
FBI Superfast DTMF (1400 Hz ACK Tone or 2300 Hz ACK Tone)
Pulse 3/1, 3/1 Checksum, 4/2 (1400 Hz ACK Tone or 2300 Hz ACK Tone)
Radionics Modem II, Radionics Modem IIe , and Modem IIIa
2
Seriee FSK and DTMF
SIA V.21, 110/300 baud
SIA Bell 103, 110/300 baud
Robofon
Telim
Inputs
Input Description
1 Used as an end-of-line (EOL) supervised loop. Detects open, short,
and normal states. Terminate this input with a 10 kΩ EOL resistor.
2 Used for intercept inhibit to force the C900V2 into Fallback mode
for at least two minutes.
3 Used for intercept override, allowing users to switch between in-
tercept and fallback modes.
Outputs
Out-
put
Description
1 Provides local annunciation if the power to the C900V2 is lost or
the CPU fails.
2 Provides local annunciation if the connection to the monitoring
center is lost.
3 Provides local annunciation whenever the C900V2 is in intercept
mode.
4 Controllable from the monitoring center and the Conettix D6200
Programming/Administration Software (default is open).
Intercept and Fallback Modes
Intercept Mode: The C900V2 connects the dialer to the
network. Intercept mode remains on as long as the
C900V2 remains in continuous contact with the
Conettix D6600 Communications Receiver/Gateway.
Fallback Mode: The C900V2 connects the dialer to the
telephone line, removing itself from the telephone
circuit. Fallback mode occurs if the C900V2 loses
contact with the Conettix D6600 Communications
Receiver/Gateway, loses power, or stops operating
correctly.
LED Indicators
The C900V2 has two dual-colored LEDs that indicate the
module's status (the SYSTEM LED and the DIALER LED).
Modular Jacks
The C900V2 module has three modular jacks.
Panel Jack: Connects to a dialer through a modular
telephone cord (D162).
TELCO Jack: Connects to a PSTN line through a
modular telephone cord (D162).
Ethernet Jack: Connects to the Ethernet data network
through an Ethernet cable. For 10BASE-T, the cable
must be Category 3 or better. For 100BASE-T, the cable
must be Category 5 or better.
Polling and Supervision
Conettix C900V2 polling helps the Conettix D6600
Communications Receiver/Gateway to perform
supervision.
Web Programming Tool
The web programming tool makes the C900V2 configuration
process simple and convenient, similar to browsing a web site.
After obtaining an Application ID, installers can go to
www.c900v2.com from a computer with internet access and
configure the C900V2 for the preferred central station.
Certifications and Approvals
Region Certification
Europe CE 1999/5/EC, EN55022: 1998,
EN50130-4: 1996 +A1: 1998 +A2: 2003,
EN60950-1: 2001, EN61000-3-2,
EN61000-3-3, EN61000-4-2: 1995 +A1:
1998, EN61000-4-3: 1995 +A1: 1998,
EN61000-4-4: 1995, EN61000-4-5:
1995, EN61000-4-6: 1996,
EN61000-4-11: 1994, TBR21: 1998
Belgium INCERT B-509-0040/a
USA UL AMCX: Central Station Alarm Units
(UL1610, UL1635), AMCX7: Central
Station Alarm Units Certified for Canada
(cULus), APAW: Police Station Alarm Units
(UL365, UL464), APAW7: Police Station
Alarm Units Certified for Canada (cULus),
APOU: Proprietary Alarm Units (UL1076),
APOU7: Proprietary Alarm Units Certified
for Canada (cULus), NBSX: Household
Burglar Alarm System Units (UL1023),
NBSX7: Household Burglar Alarm System
Units Certified for Canada (cULus), UTOU:
Control Units and Accessories - Household
System Type (UL985), UTOU7: Control
Units and Accessories - Household System
Type Certified for Canada (cULus)
UL864, 9th edition
FM
CSFM 7300-1615: 180 and 7167-1615:
223 July 2008
www.boschsecurity.com Bosch Security Systems B.V.