Bosch Appliances 8-Dec Home Security System User Manual


 
172 | Detectors and Accessories | Motion PIR/Microwave
ISM‑BLD1
Blue Line TriTech Detec-
tors
Features
11 m x 11 m (35 ft x 35 ft) broad coverage
EN50131-2-4 Grade 2 compliant
Dual detection technologies with advanced signal
processing
Flexible mounting height from 2.3 m to 2.7 m (7.5 ft to
9 ft)
No range or height adjustments required
Supervised microwave; microwave range can be
adjusted
Eight detection layers including optional look-down
zone
Draft and insect immunity
Temperature compensation
Combined cover and wall tamper
The ISM-BLD1 TriTech® Detectors use a combination of
passive infrared (PIR) and microwave detection
technologies with advanced signal processing. These
unobtrusive detectors are simple to install and do not need
field adjustments.
These detectors are available in three frequencies:
Frequency Detector
9.9 GHz ISM-BLD1- F3
10.525 GHz ISM-BLD1- F1
10.687 GHz ISM-BLD1- F4
Functions
Advanced Signal Processing
Adaptive processing adjusts to background disturbances,
reducing false alarms without sacrificing intruder detection.
First Step Processing (FSP) almost instantly responds to
human targets without producing false alarms from other
sources. FSP adjusts the detector's sensitivity based on
signal amplitude, polarity, slope, and timing. This eliminates
the need for the installer to select the sensitivity level. Each
sensor (PIR and microwave) processes signals individually,
and both sensors must agree there is an alarm before the
alarm relay activates.
Test Features
An externally-visible, tricolor (blue, yellow, green) alarm
LED (light-emitting diode) indicates each sensor's status.
Supervised Microwave
The microwave circuit is fully-supervised. If the microwave
subsystem fails, the PIR subsystem provides single
technology coverage.
Draft and Insect Immunity
The sealed optical chamber prevents drafts and insects
from affecting the detector.
Temperature Compensation
The detector adjusts its sensitivity to maintain its ability to
identify human intruders at critical temperatures.
Certifications and Approvals
Region Certification
Belgium INCERT ISM-BLD1-F1: B-509-0014/c
Russia GOST ISM-BLD1-F1: GOST 12997-84, GOST R
50009-2000, GOST R 51317.3.2-99,
GOST 51317.3.3-99, GOST R MEK
60065-2002
France AFNOR ISM-BLD1-F3: NF, A2P (282112-00)
Brazil ANATEL ISM-BLD1-F1: 0251-06-1855
Europe ISM-BLD1-F1 complies with EN50131-2-4 Grade 2
Installation/Configuration Notes
Application Information
Coverage Patterns
Note An alarm occurs only when an intruder is
detected in areas in which the PIR and
microwave patterns overlap.
Bosch Security Systems B.V. www.boschsecurity.com
5