Outputs
Control outputs
Low: 0 to 0.5 V Imax = 0.1 mA Active
High: 7 to 9 V Imax = 0.1 mA Standby
Note The MAGS-S active glass break detector, the
EKOM 11 contact-less transmitter and the UP
370 T Matchtec detector are not suitable for
connection to the IC 400 LSN.
Parts Included
Type Qty. Component
IC 400 LSN 1 Universal expander
Technical Specifications
Operating voltage
LSN part
+12 V to +33 V
Separate power supply
10.8 V to 30 V
Current consumption
LSN part
3.84 mA
By separate power supply
Max. 20 mA
Inputs/outputs
Inputs
2 differential detector zones
(1 x alarm, 1 x tamper)
Terminating resistance
12 kilohm
Anti-masking/fault
1 input active when 0 V
Tamper contact
Switched internally in series with
tamper input
Outputs
Walk test and alarm memory
Power supply output for connected detectors
I
20 mA
V
9.6 V ± 0.36 _V
Housing
Material
ABS
Color
White, RAL 9002
ambient temperature
-10 °C to +55 °C
Dimensions (H x W x D)
85 x 85 x 28 mm
Protection category IP 40
Environmental class II
Ordering Information
IC 400 LSN Universal Expander
For connecting conventional motion detectors
to the local security network LSN