Bosch Appliances 8-Dec Home Security System User Manual


 
Control Panels, Control Centers, and Keypads | Solution Series | 23
Automatic Battery Testing
The system performs a battery test each time a user arms
the sys-tem, and automatically every four hours. When the
system detects a low capacity back-up battery, it creates a
low battery fault.
Event Memory Recall
Event Memory Recall plays the last 40 system events,
including all alarms, system arming, and system disarming.
If the control panel is partitioned, Event Memory Recall
plays the last 10 system events.
Programmable Ring Burst Time
Telephone ring times might be longer or shorter depending
on the technology in a system. Different timing can cause
control panels to answer calls that should be answered by
an answering machine, fax, or a person. Users can program
the control panel for the correct ring burst time. Adjust the
ring time from 0 ms to 1200 ms in 5 ms increments.
Call Forwarding
The telecommunications provider must offer a call
forwarding option. Users can program call forwarding
modes to operate when the system is armed in the AWAY
Mode.
Call Forward Modes
Immediate On: Redirects all incoming calls to another
number, including mobile phones, pagers, and
answering services. The telephone called first does not
ring.
No Answer: Redirects all incoming calls to another
number when the telephone that was called first is not
answered within 20 seconds. Outgoing calls can still be
made from the first telephone.
Certifications and Approvals
Region Certification
Europe CE
A-Tick Supplier Code N663
New Zealand Telepermit PTC 211/98/083
Installation/Configuration Notes
Compatibility Information
RF Receivers RE005E RF Receiver with Outputs
RF Transmitters RE012E Two-channel Hand-held Transmitter
RE013E Four-channel Hand-held Transmitter
Codepads
CP105A Night Arm Station
CP500AW LED Area Addressable
CP500ALW LCD Area Addressable
CP500PW LED Partitionable
CP516LW LCD
CP516W LED
Modules MO144 Universal Timer Module
Technical Specifications
Enclosure
Dimensions: 30.6 cm x 26.2 cm x 8.4 cm
(12 in x 10.3 in x 3.3 in)
Packed in carton
Weight: 2.5 kg (5.5 lb)
Environmental Considerations
Relative Humidity: 10% to 95% non-condensing
Temperature (Operating): 0°C to +45°C (+32°F to +113°F)
Power Requirements
Current Draw (Standby): 65 mA
Current Draw (Alarm): 115 mA
Current Draw (with Codepad): 105 mA
Primary: 240 VAC, 18 VAC at 1.3 A from a TF008
Plug Pack
Secondary: 12 VDC, 6 Ah from a rechargeable sealed
lead/acid battery
Trademarks
MS-DOS
®
is a registered trademark of Microsoft Corporation in the United
States and/or other countries.
Ordering Information
CC488P Solution Ultima 880 Control Panel
Includes assembled printed circuit board
(PCB), power connector, EOL resistors, ter-
minals, and battery leads.
CC488P
Accessories
CC808 Direct Link Cable
Cable to connect CC816 Alarm Link Software
(A‑Link) to Solution 862, Solution 880 Ultima,
and Solution 16 Control Panels.
CC808
CC811S Modem Module
Modem module for Solution 862, 880, and Ul-
tima Control Panels for SMS reporting.
CC811S
CC891 Programming Key
Uploads and downloads program settings for
Solution 16, Solution 862, Solution 880, and
Ultima Control Panels.
CC891
Enclosure with Transformer (220 VAC)
Metal enclosure with 220 VAC transformer,
fuse and terminal block, front and rear tamper
switch, and key lock on door.
EDM-ENCL-KIT
www.boschsecurity.com Bosch Security Systems B.V.
1