Bosch Appliances 8-Dec Home Security System User Manual


 
320 | LSN Peripherals | LSN Motion PIR/Microwave
UP 370 T LSN Matchtec
Detector, Antimask
Features
Linking of passive infrared and ultrasound systems
Range of 6–10 m
Temperature compensation
Alarm memory
Programming of the detector is carried out via
programming software in the corresponding LSN
control panel
Alarm, tampering and faults are evaluated via the LSN
bus
Antimasking
The UP 370 T LSN is used to monitor rooms for
unauthorized entry.
The detector reveals human movement in all directions
using a passive infrared system and an ultrasound system.
10 m wide-angle version with antimasking.
Functions
The UP 370 T LSN Matchtec motion detector detects human
movement in all directions using a passive infrared system
(PIR) and an ultrasound system (US).
A pyroelectric sensor is positioned in the focal point of a
mirror. The shape of the mirror provides an almost
comprehensive monitoring area.
Temperature compensation ensures that false alarms are
suppressed. This is realized by linking the passive infrared
and ultrasound systems.
The detection zone of the detector corresponds to a
maximum area of 50 m
2
and is limited by walls, doors,
windows etc.
Detection zone settings:
– Standard: detection area 7 m x 7 m
– Reduced: detection area 5 m x 5 m
The use of several detectors in the same room is possible.
Note minimum distance between detectors!
Detector system function
In disarmed status, the ultrasound transmitter is switched
off. The detector acts as a passive infrared detector (PIR)
in this status. Antimasking continues to function
independently. The US detection system is switched back
on with the walk test.
Monitoring of detector function
A self test is always conducted when adding the power
supply. The detector also conducts a periodic self test.
Function errors, e.g. sensor failure, are displayed as faults
by the continuously lit yellow LED.
Antimasking
The antimasking (saving/non-saving) is set using the control
panel software. For masking tests that limit motion
detection, an antimask message is generated and, for walk
tests, the masking indicator (green LED) is activated. The
antimasking range is approx. 0.2 m, depending on the
masking material.
In order to ensure operational reliability, sprayed detector
covers must be replaced. Cleaning is not sufficient.
The detection sensitivity has adjustable settings.
Certifications and Approvals
Region Certification
Europe CE UP 370 T LSN
Germany VdS G 101100, C UP 370 T LSN
Installation/Configuration Notes
The UP 370 T LSN has a 4-wire element and requires
separate auxiliary voltage. Shielded installation cable must
be used to connect the detector.
Installation
Corner and 45° installation (right/left) is possible without
accessories.
An installation height of > 2.2 m is recommended for
detectors with antimasking.
Point the detector at 2° downward for installations higher
than 2.2 m.
For optimal performance, position the detector in a location
where the intruder's anticipated path is at 45° to the
detector axis.
Bosch Security Systems B.V. www.boschsecurity.com