Bosch Appliances 8-Dec Home Security System User Manual


 
372 | LSN Peripherals | LSN Expansion Modules
Connecting conventional detectors
1 Control panel
2 LSN element
3 1-4 DC primary lines
4 Loop
Detection and control via two wires
In local security networks, detection and control functions
are performed via the LSN line. This means additional
primary lines in the control panel are not required for
control procedures.
1 Control panel
2 LSN element
3 Control
4 Loop
5 Stub
Optional KR 100 LSN relay module for LSN expanders
The KR 100 LSN relay module for LSN expanders is intended
for use in the NNK 110 LSN and NVK 100 LSN.
The KR 100 LSN is installed if the high power requirement
of the connected control elements results in these
becoming impossible to actuate directly by the LSN
expanders, or in order to enable zero-potential switching.
Up to four KR 100 LSNs can be installed per NNK 110 LSN
or NVK 100 LSN. One solder distributor is supplied per two
KR 100 LSNs.
Parts Included
Type Qty. Component
NNK 110 LSN 1 Emergency call coupler
Technical Specifications
Operating voltage
LSN part
+12 V to +33 V
Other expansion module func-
tions
+9 V to +30 V
Current consumption 2.2 mA for LSN part and 7 mA for the
other expansion module functions
Control output 1 (terminal 14) Open collector, 0 V when active
Switching voltage
Max. 30 V
Switching current
Max. 20 mA
Control output 2 (terminal 13) Open collector, 0 V when active
Switching voltage
Max. 30 V
Switching current
Max. 20 mA
Control output 2 (terminal 12) Open collector, 0 V when inactive
Switching voltage
Max. 30 V
Switching current
Max. 10 mA
Control output 3
(connection 15, 16)
Open collector, 12 V when active
Switching voltage
< 1.5 V
Switching current
Max. 100 mA
Output voltage + 12.65 V
Output current Max. 100 mA
(The total of all V
0
outputs and control
output)
Connection options 4 DC primary lines
1 - 4 primary lines (PL)
Terminal resistance
RE = 12k1 Ohm 1%
Alarm criteria
± 40% of terminal resistance
Line resistance
Max. 100 Ohm
Response time
< 200 ms
Closure monitoring Max. 100 Ohm
Ambient temperature -5 °C to +45 °C
Housing base/cover Plastic
Color RAL 9002 grayish white
Weight Approx. 400 g
Dimensions (H x W x D) 215 x 160 x 35.5 mm
Protection category IP 30
Environmental class II (VdS 2110)
KR 100 optional
Reel
Response voltage
> 7 V
Fall-off voltage
< 1 V
Reel voltage
Max. 14.3 V
Contacts
Principle 2 change-over contacts zero poten-
tial
Starting current
Max. 5 A
Permanent current
Max. 2 A
Switch-off current
Max. 1 A
Switching voltage
Max. 60 V
Switching performance
Max. 30 W
Bosch Security Systems B.V. www.boschsecurity.com
6