476 | DSRF Premises Wireless | Bosch DSRF Transmitters
Glass Type Glass Thickness
Plate 0.24 cm to 0.95 cm
Tempered 0.32 cm to 0.95 cm
Laminated 0.32 cm to 1.4 cm
Protected only if both panes of unit are broken
Wired 0.64
Sensitivity Settings
Sensitivity Setting Range
Maximum 7.6 m
Medium 4.6 m
Low 3 m
Lowest 1.5 m
Compatibility Information
Receivers Control Panels
RF3212E Solution Ultima 844, 862, and 880, CC488
RF3213E VR-8
RF3222E DS7400XiV4
RF3227E DS7240, DS7220, D6412, and D4412
RF3228E Marise
RF3249E DA (Abacus)
Recommended Products
Bosch 13-332 Sound Sensor Tester
Duracell® MN1500 or PC1500, Eveready® E91, or
Panasonic® AM-3PIXB batteries
Mounting Considerations
For the best performance, mount the RF1100E:
On flat surfaces, such as ceilings or walls.
Within clear view of the glass (there is no minimum
range).
Within 7.6 m of the glass.
Note If the window is covered with heavy drapes,
curtains, shades, blinds, and so on, mount the
RF1100E on the window frame.
Do not mount the RF1100E:
In a corner or in rooms with loud equipment such as air
compressors, bells, and power tools.
On the same wall as the glass.
On freestanding posts or pillars.
The maximum RF range of the RF1100E in an open field is
approximately 300 m. In normal residential or commercial
applications, mount the RF1100E within 100 m of its
assigned receiver.
Technical Specifications
Electrical
Battery Life: Minimum of 2 years under normal operating conditions.
Test with the recommended battery types.
Batteries: Two AA, 3 V alkaline batteries
Mechanical
Dimensions 12.2 cm x 10.5 cm x 3.3 cm
Frequency: 433.42 MHz
Environmental
Temperature (operating): 0°C to +50°C
Trademarks
Duracell® is a registered trademark of The Gillette Company.
Eveready® is a registered trademark of Eveready Battery Company, Inc.
Panasonic® is a registered trademark of Matsushita Electric Industrial Co.,
Ltd.
Ordering Information
RF1100E Glassbreak Transmitter
Equipped with two tamper switches and four
glassbreak sensitivity settings
RF1100E
Bosch Security Systems B.V. www.boschsecurity.com