Bosch Appliances 8-Dec Home Security System User Manual


 
132 | Arming Devices | LSN
Arming/disarming is carried out by using the SmartKey key
then entering the user code.
If someone is forced to disarm the intrusion alarm system,
a silent alarm (hold-up alarm) can be set off remotely via the
code keypad. The code keypad can be surface mounted or
flush mounted (outside the secure area).
Reader
Arming and disarming is carried out using an electronic key
on the reader. LED and buzzer provide information about
the status of the system as well as operation. The reader
can be surface mounted or flush mounted (outside the
secure area).
Reader and code keypad
The code keypad, used in conjunction with the reader,
allows arming and disarming of the intrusion alarm system
only after the correct combination of numbers has been
entered at the keypad.
Arming/disarming is carried out by using the SmartKey key
then entering the user code.
If someone is forced to disarm the intrusion alarm system,
a silent alarm (hold-up alarm) can be set off remotely via the
code keypad.
It can be surface mounted or flush mounted (outside the
secure area). For flush mounting, two IP55 flush-mounted
junction boxes may be used in combination, if required. One
on top of the other or next to each other.
Reader and lockable code keypad
The code keypad, used in conjunction with the reader,
allows arming and disarming of the intrusion alarm system
only after the correct combination of numbers has been
entered at the keypad. If someone is forced to disarm the
intrusion alarm system, a silent alarm (hold-up alarm) can
be set off remotely via the code keypad. The code keypad
can be surface mounted or flush mounted (outside the
secure area).
Code keypad (as autonomous code keypad)
The SmartKey code keypad with integrated reader can also
be connected as an autonomous code keypad. The code
keypad allows arming and disarming of the intrusion alarm
system only after the correct combination of numbers has
been entered at the code keypad. If someone is forced to
disarm the intrusion alarm system, a silent alarm (hold-up
alarm) can be set off remotely via the code keypad. The
code keypad can be surface mounted or flush mounted
(outside the secure area).
Keys with a security card
The system operates like a locking device. The key kit
consists of a set number of valid keys and a security card.
The control unit is initialized using the security card, and
accepts only the keys of the key kit. To order additional
keys, the security card must be sent to the manufacturer
together with the order. The keys are labeled with a
consecutive key number, a security card number and an 8-
digit identification number.
Standard key (without security card)
The keys are not numbered and can be read in as often as
required. The keys are labeled with an 8-digit identification
number.
SPE blocking element
The SPE blocking element is an additional lock for the door
and is intended to prevent unauthorized entry to the armed
area. The SPE blocking element must always be mounted in
the secure area with a kit to allow it to be fitted out for
different door types.
Blocking elements for vault doors
The E4.4 and E4.3 blocking elements are electromechanical
blocking units that are intended for installation in vault
doors or doors on safes or automatic teller machines. The
blocking elements are not used as switching equipment;
arming occurs via SmartKey. The blocking element for vault
doors is included in the forced actuation system for arming.
It is not possible to simultaneously connect an E4.4/E4.3
blocking element and an SPE blocking element and/or a
door opener relay.
Door opener relay
There is a relay for activating a door opener relay on the
control unit; 60 W DC (2 A, 30 V DC). Parameters must be
defined for connecting the door opener; activation is only
possible with an unarmed control panel and an open bolt
contact. Setting of a time delay and an activation time is
programmable. The door opener relay can also be activated
using a push-button via PL2. Simultaneous connection to a
blocking element is not possible for vault doors.
Switching point activation
There is a freely programmable C point switch output (open
collector output) 12 V, max. 80 mA on the control unit.
Bolt contact/magnetic contact
A conventional bolt contact should be fitted to the control
unit (not part of the scope of delivery).
A standard magnetic contact can be connected to the
control unit (not part of the scope of delivery).
Certifications and Approvals
Region Certification
Europe CE SE 320 LSNi
SmartKey
Germany VdS G 106065, C SE 320 LSNi
Coun-
try
Certification SE 320 LSNi
DE VdS G 106065, C