Bosch Appliances 8-Dec Home Security System User Manual


 
44 | Control Panels, Control Centers, and Keypads | 7000 Line
Outputs
The DS7240V2 has four on-board programmable outputs
that may be expanded up to 20.
PO 1: terminals can be configured as an alarm power
output. The default configuration for PO 1 makes it a dry
contact, Normally-Open (NO) relay.
PO 2: can be used with Alarm + as a supervised siren driver.
Connect an approved 4 Ω or 8 Ω speakers. Alternatively,
PO 2 can sink up to 500 mA, 12 VDC.
PO 3 and PO 4: can be configured for Alarm Output. These
outputs can sink 500 mA, 12 VDC each.
Certifications and Approvals
Region Certification
Europe CE 1999/5/EC, 2006/95/EC, 2004/108/
EC; EN 55022:2006 + A1:2007, Class B;
EN 50130-4 w/A1:1998 + A2:2003;
EN61000-3-2:2006;
EN61000-3-3:1995; EN 60950-1:2001;
TBR21:1998
EN501-31 Compliance
Russia GOST GOST 12997-84, GOST R MEK
60065-2002, GOST R 50009-2000,
GOST R 51317.3.2-99, GOST R
51317.3.3-99
France AFNOR NF, A2P (122076-00)
China CCC 2005031902000137
Sweden INTYG Nr05-14
Brazil ANATEL 1240-05-1855
The DS7240V2 Control Panel complies with the following certifications,
approvals, and standards.
Country Certification/Listing Number
Europe EN50131-1 grade 2
Sweden SSF 1014
Installation/Configuration Notes
Compatibility Information
Batteries D126 12 V, 7 Ah Standby Battery
D1218 12 V, 18 Ah Standby Battery
D1240 12 V, 4 Ah Standby Battery
Keypads DS7445i LED Keypad
DS7445V2 LED Keypad
DS7446KP LCD Keypad
DS7447E LCD Keypad
DS7447i Alpha Numeric Keypad
DS7447V2 LCD Keypad
Fire
Detectors
D132A Smoke Detector Reversing Relay
DS250 Photoelectric Smoke Detector
DS250TH Photoelectric Smoke Detector with
heat-sensing thermistor
DS284 Photoelectric Smoke Detector
DS284TH Photoelectric Smoke Detector with
heat-sensing thermistor
DS284THS Photoelectric Smoke Detector with heat-sensing
thermistor and sounder
Wireless
Products
RF280ETHS Wireless Photoelectric Smoke Detector with
heat-sensing thermistor and sounder
RF835E Wireless TriTech
®
Detector
RF940E Wireless PIR Detector
RF1100E RF Glass Break Detector
RF3227E RF Receiver
RF3332E Two-button Key Fob
RF3334E Four-button Key Fob
RF3401E RF Transmitter
RF3405E RF Inertia Transmitter
RF3501E RF Panic Pendant
RF3503E RF Panic Button
Modules DACM Door Access Control Module
DX2010 Eight-input Expander
DX3010 Octo-output Expander
DX3011 Octo-output Expander Package
DX3012 Octo-output Expander Package
DX4010 RS-232 Serial Interface Module
DX4010i RS-232 Serial Interface Module
DX4020 Network Interface Module
RVM4C Remote Video Module
Wiring Considerations
Up to 305 m (1,000 ft) allowed between control panel
external power supply and keypad or DACM when using
0.8 mm wire.
Up to 610 m (2,000 ft) allowed between panel/external
power supply and keypad or DACM when using 1.2 mm
wire.
No more than two keypads or DACMs (0.8 mm) or three
keypads/DACMs (1.2 mm) are recommended on any
305 m (1,000 ft) run when powered from the panel.
Parts Included
Each standard system includes:
Quantity Component
1 DS7240V2 control board
1 Universal enclosure
1 Transformer (18 VAC, 50 VA)
1 Hardware/resistor pack
Technical Specifications
Data Bus
Data Bus: 12 VDC nominal
Bosch Security Systems B.V. www.boschsecurity.com
1