Bosch Appliances 8-Dec Home Security System User Manual


 
4 | Control Panels, Control Centers, and Keypads | Easy Series
Installation/Configuration Notes
Compatibility Information
PSTN Communicator
(Integrated)
Formats: BSIA Fast Format, Contact ID, SIA,
(Voice Dialer)
Personal Messaging: SMS Text and Voice
IP Communicator
1, 3
Conettix IP C900V2 Dialer Capture Module
GSM Communica-
tor
1, 3
Conettix ITS-300GSM Communicator
Radio Communica-
tors (SAFECOM)
1, 2
SC2104 Series Slave Communicators
SC3100 Series Data Transfer Radio Communica-
tors
SC4000 Series Full Data Transfer Radio Commu-
nicator
Magnetic Contacts
1
All Bosch magnetic contacts, including recessed,
terminal connection, miniature, overhead door,
and surface mount.
Intrusion Detectors
1
All conventional Bosch intrusion detectors, includ-
ing Blue Line, seismic, PIR, TriTech, photoelectric,
and TriTech PIR Microwave.
Two-wire and
Four‑wire Smoke De-
tectors
1,3
Conventional Bosch 12 V smoke, heat, and photo-
electric smoke detectors.
Hardwire Expansion
Module
DX2010 Input Expander
Interface Module
1, 2
D132A Smoke Detector Reversing Relay
wireless Local Secur-
ityNetwork (wLSN)
Devices
1
All Bosch wLSN devices, including the wLSN Hub
(wireless expansion module), wLSN PIR and dual
technology motion detectors, wLSN glass break
detectors, wLSN key fobs, wLSN inertia sensors,
wLSN door and window contacts, wLSN relay out-
puts, and wLSN sirens.
1
Assorted literature is available. Refer to the appropriate data sheet, bro-
chure, installation guide, or user guide for additional details.
2
Only sold in specific countries. Does not comply with CE.
3
Availability varies according to sales regions.
Technical Specifications
Dimensions
Control Center: 12 cm x 17.7 cm x 2.5 cm
(4.7 in. x 7 in. x 1 in.)
AE1 Enclosure: 37 cm x 31.75 cm x 8.5 cm
(14.5 in. x 12.5 in. x 3.4 in.)
Environmental Considerations
Relative Humidity: 93% ±5% at 32°C ±2°C (+90°F ±2°F)
Temperature (Operat-
ing):
-10°C to +49°C
(+14°F to +120°F)
Temperature (Storage): -10°C to +55°C
(+14°F to +130°F)
Environmental Class II
Input Points
Maximum Number of Input
Points:
32
Hardwire, Wireless, or
Combination Input Points:
Eight on-board
Hard-wire single, zone-doubling, dual
end-of-line (EOL) tamper, or wireless.
Input 1 also supports two-wire smoke
detectors, all input points support four-
wire detectors.
Enclosure tamper input (does not reduce
input point capacity).
Hardwire Expansion Input
Points:
Up to 24 with three DX2010 Input Expander
Modules (32 total).
Each DX2010 provides eight additional input
points. The Easy Series Intrusion Control Panel
supports up to three modules.
Wireless Expansion Input
Points:
Up to 32 with the wLSN Hub
Outputs
On-board: Four
Configurable solid state
Internal siren driver option for speakers
(output 4 only)
Wireless: Four
Number of…
Control Centers: Four
Audible voice prompts included
Accepts passcodes, token, or the wLSN
key fob for user arming and disarming
DX2010 Expansion Mod-
ules:
Three on the Option Bus
wLSN Hubs: One on the Option Bus
Users: Up to 20 (20 passcodes, 20 tokens, and 20
wLSN key fobs)
Events: 500 history events, stamped with time and date
Power Requirements
Primary Voltage Source: 110 V, +10% or -15% (47 Hz to 62 Hz)
230 V, +10% or -15% (47 Hz to 62 Hz)
Primary Voltage Input
(AC):
18 V (47 Hz to 62 Hz)
Primary Voltage Input
(DC):
18 V non-polarized
Secondary Voltage Input
(DC):
12 VDC, 7 Ah or 18 Ah sealed lead acid re-
chargeable battery
Total Power: 1.4 A
Auxiliary Power: 1.0 A
Easy Series Kit Ordering Information
Europe, Middle East, and Africa
Kits include one control panel, enclosure, tamper switch, oval control cen-
ter, wire‑in power supply (100 V to 250 V), and two RFID tokens unless
noted otherwise.
Language Commercial Type Numbers
Kit Voice Module
None
1
ICP‑EZUAWT‑00
2
None
1
None
1
ICP‑EZ2AWT‑00
None
1
English ICP‑EZ2AWT‑01 ICP‑EZV2‑ENF
Bosch Security Systems B.V. www.boschsecurity.com
1