Bosch Appliances 8-Dec Home Security System User Manual


 
278 | Detectors and Accessories | Magnetic Contacts Surface Mount
EMK 46 AT Z Surface-
Mount Magnetic Contact
Features
Conventional surface-mount magnetic contact
VdS class B
Head-on or parallel surface mounting
Conventional perimeter protection
Conventional magnet contacts are used for tear-off
surveillance of windows and doors.
Certifications and Approvals
Region Certification
Europe CE EMK 46 AT Z
Germany VdS G 191563, B EMK 46
Installation/Configuration Notes
Installation notes
Installation can be head-on or parallel on the door or
window frames.
1 Contact
2 Magnet
3 Installation offset
Surface mounting
When used on metal frames, the plastic bases must be
used.
The supply lines need to be measured electrically
before connection.
The contact and the magnet (6 x 30 mm) can only be
inserted in the surface mounting housing in conjunction
with the plastic sleeve.
Installation on ferromagnetic materials is only
permissible with the washer components supplied.
Lateral installation offset: max +/- 3 mm.
Distances diagram
Surface mounting with magnet 6 x 30 mm
1 Extraction
2 Proximity switch part
Flush mounting
Installation in ferromagnetic materials is not
permissible.
Installation can be completed with or without a plastic
sleeve. If no plastic sleeve is used, the components
should be fixed in the bores.
Distances diagram
Head-on installation with magnet 6 x 30 mm
1 Extraction
2 Proximity switch part
Parts Included
Type Qty. Component
EMK 46 AT Z 1 Surface-mount magnetic contact
incl. flange, sleeves, and surface-mounting
housing with accessories
Bosch Security Systems B.V. www.boschsecurity.com
5