Bosch Appliances 8-Dec Home Security System User Manual


 
Conettix - Information Transport Solutions | Conettix - Receiver/Gateway | 389
Technical Specifications
Electrical
Power Requirements
AC Nominal Operating Range: 120 V or 230 V
AC Maximum Operating Range: 100 VAC to 120 VAC, 220 VAC to 230
VAC, 50 Hz or 60 Hz, 2.5 A maximum
Standby Power: Uninterruptible power supply (UPS)
containing a sealed lead-acid battery,
12 V, 7 Ah to 18 Ah
Current Requirements
One Line Card Installed: Battery: 800 mA
UPS AC Standby: 350 mA
For Each Additional Line Card or Ter-
minal Card Pair:
Battery: 210 mA
UPS AC Standby: 35 mA
One Network Communications Card
Installed:
Battery: 10 mA
UPS AC Standby: 10 mA
Mechanical
Automation Outputs
Automation Outputs: SIA mode
6500 mode
Enclosure
Rack Mount Dimensions (4U): 18 cm x 48.3 cm x 49.5 cm
(7.0 in. x 19.0 in. x 19.5 in.)
Standalone Dimensions: 18 cm x 45 cm x 49.5 cm
(7.0 in. x 17.75 in. x 19.5 in.)
Weight: 8.7 kg (19 lb)
Telephone
Telephone: RJ11C modular jacks, with 26 AWG
or larger wire diameter
Ringer Equivalence Number (REN)
REN: 0.4 B
Industry Canada (IC) REN: 0.2
Display
Screen Dimensions: 1.8 cm x 15.2 cm (0.7 in. x 6.0 in.)
dot matrix LCD, 5 x 7 dots per char-
acter. Shows two separate lines, 40
characters per line.
Indicators: LED display section indicates receiv-
er status and power.
Inputs and Outputs
For Automation Computer Connec-
tion:
One RS-232 interface port COM3
For External Serial Printer, PC, Mo-
dem, or Network Connection:
One RS-232 interface port COM4
For Parallel Printer Connection: One parallel printer port
Number of Programmable Inputs: Two (wire harness included)
Number of Programmable Outputs: Two (wire harness included)
Optional Input
For Optional Network Communica-
tions Expansion:
One RS-232 interface port COM1
Environmental
Temperature (Operating): 0°C to 50°C
(+32°F to +122°F)
Trademarks
Microsoft
®
, Windows
®
, and Windows NT
®
are registered trademarks of Mi-
crosoft Corporation in the United States and/or other countries.
Ordering Information
Conettix D6600 Communications
Receiver/Gateway
Supports communications through PSTN,
LAN/WAN, or both. Supports 32 telephone
lines and 3200 network accounts. Supports
two-way audio, Caller ID, ANI, and DNIS.
D6600
Accessories
3200 Account Conettix IP
Security Key (LPT)
Designed for parallel ports. Allows each Con-
ettix Communications Receiver/Gateway to
support a maximum of 3200 IP accounts.
D6201
3200 Account Conettix IP
Security Key (USB)
Designed for USB ports. Allows each Conettix
Communications Receiver/Gateway to sup-
port a maximum of 3200 IP accounts.
D6201-USB
500 Account Conettix IP Security Key (USB)
Designed for USB ports. Allows each Conettix
Communications Receiver/Gateway to sup-
port 500 IP accounts.
D6201-500-USB
Conettix D6610 CPU Line Card
Provides programmable FLASH memory for
firmware upgrades. Includes a 20,000-event
history buffer and a computer micro-process-
or.
D6610
Conettix D6615 CPU Terminator Card
Provides a shielded interface between the Con-
ettix D6610 CPU Line Card and external con-
nections to automation database computers
and printers.
D6615
Conettix D6641 Telephone Line Card
Provides DSP technology. Answers and de-
codes signals from up to four telephone lines.
D6641
Conettix D6645 Telephone Line Terminator
Card
Provides isolation and transient suppression
to the Conettix D6641 Telephone Line Card.
D6645
Conettix D6672 Com 1 Expansion Kit
Creates a third serial port on the Conettix
D6600 Communications Receiver/Gateway.
Provides a DB9 male connector and transient
protection.
D6672
Conettix D6680 Ethernet Network Adapter D6680-E120
P6601 Battery Cable
Connects a 12 VDC power source to the Con-
ettix D6600 Communications Receiver/Gate-
way.
P6601
P6602 Input and Output Cable
Connects to the receiver and provides use of
the input and output lines.
P6602
P6603 Acknowledgement Button
Spare acknowledgement button.
P6603
www.boschsecurity.com Bosch Security Systems B.V.
7