Bosch Appliances 8-Dec Home Security System User Manual


 
Detectors and Accessories | Magnetic Contacts Recessed Mount | 259
EMK 46 S Z Flush-Mount
Magnetic Contact
Features
Conventional flush-mount magnetic contact
VdS class C
Tamper switch
Head-on flush mounting
Conventional perimeter protection
Conventional magnet contacts are used for tear-off
surveillance of windows and doors.
Certifications and Approvals
Region Certification
Europe CE EMK 46 S Z
Germany VdS G 196041, C EMK 46 S
Installation/Configuration Notes
Installation notes
Installation is head-on in door or window frames.
Installation can be completed with or without a plastic
sleeve. If no plastic sleeve is used, the components
should be fixed in the bores.
Installation in ferromagnetic materials is not
permissible.
The supply lines need to be measured electrically
before connection.
1 Contact
2 Magnet
3 Installation offset
Distances diagram
1 Extraction
2 Proximity switch part
Note: If the attached magnets are touching each other, there will
be no tamper zone!
Parts Included
Type Qty. Component
EMK 46 S Z 1 Built-in magnetic contact
incl. flange and sleeves
Technical Specifications
Type of installation Flush, head-on
Permissible operating voltage Max. 40 V_
Contact type 1-pin (normally) open contact
Permissible contact load 6 VA
Max. 100 V_
Max. 500 mA
Protection category IP 67
VdS environmental class IV
Permissible
ambient temperature
-25 °C to +70 °C
Housing
Material
ABS
Color
White
www.boschsecurity.com Bosch Security Systems B.V.
5