Bosch Appliances 8-Dec Home Security System User Manual


 
Detectors and Accessories | Accessories | 289
Wiring Considerations
The three module wires attach to the terminal block of the
Blue Line detector.
Parts Included
Quant. Component
1 Nightlight module
1 Test filter
1 Literature pack
Technical Specifications
Environmental Considerations
Complies with EN50131 Environmental Class II, Security Grade 2
Relative Humidity: Up to 95% non-condensing
Up to 85% for UL installations
Temperature (operating): -10°C to +49°C (+14°F to +120°F)
For UL Listed product installations,
0°C to +49°C (+32°F to +120°F)
Mechanical Properties
Color: White
Dimensions: 2.5 cm x 6.4 cm x 3.2 cm
(1.0 in. X 2.5 in. X 1.25 in.)
Material: High-impact ABS plastic
Output
Light Intensity: 0.1 cd at 30 cm (1 ft)
Power Requirements
Current Draw
(LEDs lit):
Brightness level set low: 40 mA
Brightness level set high: 75 mA
Standby Power: No internal standby battery. Standby power must be
provided by the control unit or by a UL Listed burglary
power supply.
Ordering Information
ISM‑BLA1‑LM Blue Line Nightlight Module
Fits all Blue Line detectors
ISM-BLA1-LM
www.boschsecurity.com Bosch Security Systems B.V.
5