Bosch Appliances 8-Dec Home Security System User Manual


 
124 | Arming Devices | LSN
SE 60 LSNi SmartKey
Blocking Unit
Features
The SE 50 LSNi conventional control unit is
programmable via the control panel
The SPE blocking element is controlled via the
intrusion control panel
The SPE blocking element is suitable for various types
of doors
The SE 60 LSNi SmartKey blocking unit is used as a
mechanical lock for doors.
System Overview
1 SPE blocking element
2 SE 60 LSNi control unit
3 Bolt contact
4 LSN control panel
Functions
The SE 60 LSNi control unit controls the SPE blocking
element depending on the state of the bolt contact and/or
the intrusion control panel. When the door is closed (bolt
contact is activated), the bolt of the SPE blocking element
is automatically engaged. When the door is unlocked, the
bolt is disengaged if the detection area is disarmed. When
the detection area is activated, the bolt remains engaged,
thus preventing unintended access to the area. If no bolt
contact is realized, the bolt of the SPE blocking element is
engaged by the activation signal issued by the control panel.
SE 60 LSNi
The SE 60 LSNi control unit processes the status reports of
all components in the system, communicates these reports
to the intrusion alarm system and controls the SPE blocking
element. The control unit has a lock line for connecting bolt
contacts and two primary lines for connecting e.g. magnet
contacts. The control unit is mounted in the secure area.
SPE blocking element
The SPE blocking element is an additional lock for the door
and is intended to prevent unauthorized entry to the armed
area. The SPE blocking element must always be mounted in
the secure area with a kit to allow it to be fitted out for
different door types.
Motorized block function: All blocking elements for an area
are engaged and disengaged simultaneously.
A conventional bolt contact should be fitted to the control
unit (not part of the scope of delivery).
A conventional standard magnet contact can be connected
to the control unit (not part of the scope of delivery).
Certifications and Approvals
Region Certification
Europe CE SE 60 LSNi
SmartKey
Germany VdS G 106062, C SE 60 LSNi
Coun-
try
Certification SE 60 LSNi
DE VdS G 106062, C
Installation/Configuration Notes
Note The SmartKey is fully operational only in
conjunction with a blocking element.
The SPE blocking element is always mounted in the secure
area with a mounting kit.
If several LSN SmartKey systems need to block
simultaneously in one area (motorized block locking
function), the control units must be in the same LSN
processing assembly (on LVM for UEZ, on NV 120 for UGM).
SE 60 LSNi without bolt contact:
Due to the time shift caused by the LSN, up to four
SE 60 LSNi can be activated in 200 ms (not arming time).
In general, a bolt contact should be mounted.
Bosch Security Systems B.V. www.boschsecurity.com