Bosch Appliances 8-Dec Home Security System User Manual


 
184 | Detectors and Accessories | Motion Outdoor
Certifications and Approvals
Region Certification
Europe CE 89/336/EEC, EN55022: 1998 +A1:2000
+A2:2003, EN50130-4: 1996 +A1:1998
+A2:2003, EN61000-3-3: 1995
+A1:2001, EN61000-4-2: 1995
+A1:1998 +A2:2001, EN61000-4-3:
2002 +A1:2002, EN61000-4-4: 1995
+A1:2000 +A2:2001, EN61000-4-5:
1995 +A1:2001, EN61000-4-6: 1996
+A1:2001, EN61000-4-11" 1994
+A1:2001, EN300 440-1 V1.3.1:
2001-09, EN300 440-2 V1.1.1: 2001-09
Belgium INCERT B-509-0038
Poland CNBOP 58/03
Russia GOST OD850-F1 only: DE.AE63.B03457
USA UL OD850-F1 only: ANSR: Intrusion Detection
Units (UL639), ANSR7: Intrusion
Detection Units Certified for Canada (ULC-
S306)
FCC OD850-F1 only: ESVOD850-F1
China CCC OD850-F1-CHI only:
2004031901000039
Brazil ANATEL OD850-F1 only: 0873-03-1855
Singapore iDA OD850-F1 only: #LPREQ-S0155-2004
Australia C-tick
Europe IEC IP=54 per IEC 60529
OD850-F2 only: Complies with EN50131-1 grade 2
Installation/Configuration Notes
Top View
Standard Broad Coverage: 15 m x 15 m (50 ft x 50 ft)
Side View
Standard Broad Coverage: 15 m x 15 m (50 ft x 50 ft)
Mounting Considerations
Wall Mounting: The OD850 detectors can be mounted
directly on a wall or on the supplied B335 Swivel Mount
Bracket. Alternatively, they can be mounted directly on
a standard rectangular electrical box.
Ceiling Mounting: The detectors can be mounted on a
ceiling using the optional B338 Ceiling-Mount Bracket.
Power Considerations
Power Limits: Input power must be provided by an
Approved Limited Power Source. All outputs must be
connected to SELV (safety extra-low voltage) circuits
only.
Standby Power: This detector has no internal standby
battery. For UL Listed product installations, 4 hr
(248 mAh) of standby power must be supplied by the
control unit or by a UL Listed burglary power supply.
Technical Specifications
Enclosure Design
Dimensions: 16.5 cm x 8.25 cm x 6.35 cm
(6.5 in. x 3.25 in. x 2.5 in.)
Material: Polycarbonate
Properties: Weather and vandal resistant
Weight: 1.4 oz (40 g)
Environmental Considerations
IP Rating: 54
Relative Humidity: 0% to 95% non-condensing
Temperature (Operating): -40°C to +54°C (-40°F to +130°F)
OD850-F2: Complies with Environmental Class III
(EN50130-5)
Outputs
Alarm: Do not use with capacitive or inductive loads.
Form A: Normally-closed contact opens on alarm.
Form C: Timed relay contact alternates state on alarm and fol-
lows an installer programmable timer.
Contact Rating: 3 W, 125 mA maximum, 25 VDC maximum for
DC resistive loads; and protected by a 4.7 Ω, ½ W resistor in the
common C leg of the relay.
Tamper: Normally-closed (with cover on) contacts rated 125 mA maxi-
mum, 25 VDC maximum
Power Requirements
Current: 62 mA maximum
Input Power: 10 VDC to 15 VDC at 22 mA standby.
Bosch Security Systems B.V. www.boschsecurity.com