Bosch Appliances 8-Dec Home Security System User Manual


 
Detectors and Accessories | Motion PIR/Microwave | 169
Self-adjusting LEDs
The LED brightness adjusts automatically to the
surrounding light level. A blue light-emitting diode (LED)
indicates TriTech+ alarms and activates during a walk test.
A yellow LED indicates microwave alarms, and a red LED
indicates PIR alarms.
Remote Walk Test LED
Users can enter a command through a keypad, a control
center, or programming software to remotely enable or
disable the walk test LED.
Alarm Memory
Alarm memory flashes the alarm LED to indicate stored
alarms for use in multiple unit applications. A switched
voltage from the control panel controls the alarm memory.
Solid State Relays
Solid state relays send silent alarm output signals to
provide a higher level of security and reliability. An external
magnet does not activate the relay. The solid state relay
uses less current than a mechanical relay, providing longer
standby capacity during a power loss.
Draft, Insect, and Small Animal Immunity
The sealed optic chamber provides immunity to drafts and
insects, reducing false alarms. Small animal immunity
reduces false alarms caused by animals less than 4.5 kg
(10 lb), such as rodents.
Remote Self Test
A remote self test initiates when the walk test input
switches to its true state. The alarm relay and alarm LED
activate for four seconds following a successful test. The
trouble relay activates, and the alarm LED flashes following
a failed test.
Input Power Supervision
When the power is lower than 8 V, a low input power trouble
condition activates the trouble relay and causes the LED to
flash. The trouble condition clears automatically when
power reaches or exceeds 8 V.
Trouble Memory
When the walk test input switches to its true state for less
than two seconds, the LED flashes to indicate the most
recent trouble condition. If there is no trouble in memory,
the LED does not flash. After twelve hours, or after the
detector receives a second walk test pulse for two seconds
or less, the LED stops flashing and the trouble memory
clears.
DIP Switch Programming
The following functions are all programmed using DIP
switch settings:
Local Walk Test LED
Remote Walk Test Input Polarity
Alarm Memory Polarity
Long and Short Range Select
MANTIS Anti-mask On and Off
Certifications and Approvals
Region Certification
Europe CE 2004/108/EC EMC Directive; 1999/5/EC
Radio Equipment and Telecommunications
Terminal Equipment, Annex V, EN 55022:
1998, +A2: 2003, ClassB; EN 50130-4:
1995, +A1: 1998, +A2: 2003; IEC
60950-1: 2001, EN 60950-1: 2001; EN
300 440-2, V1.1.2 (2004-07)
EN50131 G or H only: EN 50131-1, TS 50131-2-2
August 2004, RT 50132-2-2 July 2007, TS
50131-2-4 July 2007, RT 50131-2-4 July
2007, EN 50130-4, EN50130-5
Belgium INCERT B-509-0052/a
Sweden INTYG ISC-PDL1-WA18G only: Nr08-235
The detectors are also designed to comply with the following standards and
approvals.
Europe EN50131 EN50131-2-4 Grade 3
USA UL cULus –UL639, Intrusion Detection Units
FCC Complies with Part 15
Installation/Configuration Notes
Long-range Coverage 18 m x 25 m (60 ft x 80 ft)
www.boschsecurity.com Bosch Security Systems B.V.
5