Detectors and Accessories | Motion PIR | 159
MX934i Multiplex
PIR Intrusion Detector
Features
Motion Analyzer II processing
Unique address switch settings
Insect and draft immunity
Three sensitivity settings
The wall mount MX934i PIR Intrusion Detector uses Motion
Analyzer II signal processing to reduce false alarms. Alarm
and tamper conditions are transmitted to the control panel
through the two-wire multiplex bus. The detector’s
replaceable and pointable mirrors, three coverage patterns,
and three mounting options provide installation flexibility.
Functions
Motion Analyzer II Processing
Motion Analyzer II uses multiple thresholds and timing
windows to analyze timing, amplitude, duration, and
polarity of signals to make an alarm decision. It tolerates
extreme levels of heat and light disturbances caused by
heaters and air conditioners, hot and cold drafts, sunlight,
lightning, and moving headlights.
Insect and Draft Immunity
The sealed optical chamber provides immunity to drafts and
insects.
Three Sensitivity Settings
Standard Sensitivity: Recommended setting for
maximum false alarm immunity. Tolerates environment
extremes on this setting. Not recommended for long
range or barrier type coverage patterns. The detector is
shipped in Standard Sensitivity mode.
Intermediate Sensitivity: Recommended setting for
any location where an intruder is expected to cover only
a small portion of the protected area. Tolerates normal
environments on this setting. This setting identifies
intruders more accurately.
High Sensitivity: Fast response to intruder signals. For
use in quiet environments where heat and light
fluctuations are not anticipated.
Certifications and Approvals
Region Certification
Europe CE 89/336/EEC, 93/68/EEC, EN55022
(1998), EN50130-4: 1995, EN61000-4:
1995, EN61000-4-2: 1995,
EN61000-4-3: 1995, EN61000-4-4:
1995, EN61000-4-5: 1995,
EN61000-4-6: 1996, EN61000-4-11:
1994
73/23/EEC, IEC 60950: 1999
USA UL ANSR: Intrusion Detection Units (UL639)
Installation/Configuration Notes
Compatibility Information
Control Panels Multiplex Expansion Modules
DS7400Xi Series
G Series
DS7430
DS7436
D8125MUX
Note The DS7400Xi Series Control Panels require
ROM version 1.07 or greater.
Mounting Considerations
Select a location that is most likely to intercept an intruder
moving across the coverage pattern. Ensure the mounting
surface is solid and vibration free. Avoid hot and cold drafts,
windows, moisture, direct or reflected sunlight, and small
animals. The MX934i is not for outdoor mounting.
Note Misaligning the detector in an optional
mounting bracket can reduce range and
increase dead zones.
www.boschsecurity.com Bosch Security Systems B.V.