Bosch Appliances 8-Dec Home Security System User Manual


 
LSN Peripherals | LSN Magnetic Contacts | 361
AMK 4 S LSN Shutter Door
Contact
Features
Shutter door contact in LSN technology
For connecting to the LSN intrusion control panel
VdS class C
Tamper switch
High level of mechanical strength
Large switch distance
LSN perimeter protection
LSN shutter door contacts are used to monitor rolling,
sliding and garage doors.
Certifications and Approvals
Region Certification
Europe CE AMK 4 S LSN
Germany VdS G 101006, C AMK 4 S LSN
Installation/Configuration Notes
Installation notes
For doors < 1.5 m, one shutter door contact is required.
For doors > 1.5 m, use two shutter door contacts. Take
note of the permissible installation tolerances.
The shutter door contact consists of a sealed magnetic
switch and a magnet in a plastic casing.
The connection cable is protected over 1 m by a metal
tube.
The magnetic switch is installed at ground level
(requires a flat surface). Vehicles with rubber tires can
drive over the switch without causing problems.
The magnetic switch must not be used as a door-
stopper.
Distances diagram
1 Extraction
2 Proximity switch part
3 Standby zone
4 Tamper zone
Connecting LSN contacts
Each LSN contact is a physical LSN element (1 out of
127 possible per loop).
The length of LSN contact connection cables must be
included when planning the total line length of the LSN
loop, as LSN technology is incorporated in these
detectors.
Passive coupling elements for joining the connection
cables to the installation cable must be placed as close
as possible to the LSN contacts. The 1 m connection
cable with 2 m LSN cable length is included in the
calculation of the LSN cable length (LSN is carried into
the contacts and back out again).
Connector boxes (optional) are classified as installation
material.
Testing LSN contacts
Reed switch and microswitch functions can be checked
before installation by a high-Ohm multimeter or
continuity checker (for diode paths).
The resistance values are approximate values; a large
change in resistance is significant here.
1 Detector
2 High-Ohm multimeter
Contact open: approx. 3 MOhm
Contact closed: approx. 1 megaohm
Note Only the intrusion contact can be checked in
this way. The tamper switch of the Class C
magnetic contact can be checked by the LSN
control panel or with the LSN testing device
(software version 3.x onward).
www.boschsecurity.com Bosch Security Systems B.V.