282 | Detectors and Accessories | Magnetic Contacts Surface Mount
MSA-LZ Surface-Mount
Magnetic Contact
Features
▶
Conventional surface-mount magnetic contact
▶
VdS class B
▶
Parallel or head-on surface mounting
▶
Conventional perimeter protection
Conventional magnetic contacts are used for opening
surveillance of windows and doors.
Certifications and Approvals
Region Certification
Europe CE MSA-LZ
Germany VdS G 191568, B MS/MSA-LZ
Installation/Configuration Notes
Installation notes
•
Installation can be parallel or head-on.
•
The AG 4 surface mounting housing makes it possible
to install on ferromagnetic materials.
1 Contact
2 Magnet
3 Offset in the axial direction
Parts Included
Type Quant. Component
MSA-LZ 1 Surface-mount magnetic contact incl. 6 m
cable and AG4 surface mounting housing
with accessories
Technical Specifications
Type of installation Surface mount, parallel or head-on
Contact Normally open contact
Permissible contact load ≤ 5 Watt
Switching current 10 A to 100 mA
Switching voltage max. ≤ 110 V_
Switch tolerance
≥ 10
7
Magnet AlNiCo 500
Switch dimensions 43 x 12 x 12 mm
Magnet dimensions Ø 8 mm x 30 mm
Parallel installation distance ≤ 15 mm
Temperature range -25 °C to 70 °C
Connection cable 6 m, LiYY 4 x 0.14 mm
Protection category IP68
Bosch Security Systems B.V. www.boschsecurity.com
5