Bosch Appliances 8-Dec Home Security System User Manual


 
LSN Peripherals | LSN Magnetic Contacts | 349
MK 36 S LSN Surface-
Mount Magnetic Contact
Features
LSN surface-mount magnetic contact
VdS class C
Tamper switch
Parallel mounting
LSN perimeter protection
Magnetic contacts are used for tear-off surveillance of
doors and windows.
Certifications and Approvals
Region Certification
Europe CE MK 36 S LSN
Germany VdS G 101008, C MK 36 S LSN
Installation/Configuration Notes
Installation notes
The MK 36 S LSN must be mounted in parallel to the
magnet.
The contacts are generally installed in the door or
window frames with the magnet in the window or the
door. If the door or window is opened less than 1 cm,
the magnetic contact should not be able to detect this.
An opening of more than 3 cm must be detected.
For installation on ferromagnetic materials, the
distance plates must be used.
1 Contact
2 Magnet
Distances diagram
1 Extraction
2 Proximity switch part
3 Tamper area
4 Secure area
Connecting LSN contacts
Each LSN contact is a physical LSN element (1 out of
127 possible per loop).
The length of LSN contact connection cables must be
included when planning the total line length of the LSN
loop, as LSN technology is incorporated in these
detectors.
Passive coupling elements for joining the connection
cables to the installation cable must be placed as close
as possible to the LSN contacts. The 1 m connection
cable with 2 m LSN cable length is included in the
calculation of the LSN cable length (LSN is carried into
the contacts and back out again).
Connector boxes (optional) are classified as installation
material.
Testing LSN contacts
Reed switch and microswitch functions can be checked
before installation by a high-Ohm multimeter or
continuity checker (for diode paths).
The resistance values are approximate values; a large
change in resistance is significant here.
www.boschsecurity.com Bosch Security Systems B.V.
6