Bosch Appliances 8-Dec Home Security System User Manual


 
432 | Wireless Local Security Network (wLSN) | wLSN Peripherie
wLSN Relay Module
Features
Wiring terminals for one Form C relay rated 2 A at
30 VDC (resistive load)
Wiring terminals for supervised sensor loop input with
adjustable supervision interval
Wiring terminals for connection of optional alternate
power source (6 VDC to 14 VDC)
Externally-visible LED indicates RF signal strength
Determine suitability of chosen installation location
with RF Signal Strength (RFSS) mode
Supervised for low-battery, cover-tamper, and wall-
tamper conditions
Operates for up to 5 years on readily-obtainable AA
batteries
The wLSN Relay Module allows the control panel to switch
outputs wirelessly by turning on or off a Form C relay. The
wireless Local SecurityNetwork (wLSN) protocol allows
multiple output devices, including the wLSN Relay Module,
to be synchronized so that they all operate together using
the same cadence.
The wLSN Relay Module also accepts a supervised sensor
loop input from an external device.
Functions
Alternate Power Supply
An optional alternate external 6 VDC to 14 VDC power
supply can be connected to the relay. The alternate power
supply is used as a supplemental supply to power the relay.
Warning Do not operate the wLSN Relay Module
without batteries.
RF Signal Strength Mode
Removing the device cover and pressing the tamper switch
four times within 10 seconds of battery installation
activates the RF signal strength mode. The LED lights steady
for 5 sec and then begins to flash. A slow flash
(approximately 1 sec on, 1 sec off) indicates insufficient
signal reception. A quickly flashing LED (approximately five
times as fast as the slow flash) indicates the device is
receiving sufficient signal from the wLSN Hub.
Certifications and Approvals
Region Certification
Europe CE 1999/5/EC, IEC60950-1: 2001,
EN60950-1:2001 +A11:2004,
EN50130-4: 1996 +A1: 1998 +A2: 2003,
EN61000-4-2: 1995 +A1: 1998 +A2:
2001, EN61000-4-3: 2002 +A1: 2003
+A2: 2005, EN61000-4-4: 1995 +A1:
2001 +A2: 2001, EN61000-4-5: 1995
+A1: 2001, EN61000-4-6: 1996 +A1:
2001 +A2: 2001 +A3: 2005,
EN61000-4-11: 1994 +A1: 2001,
EN55022/ANSI C63.4: 2003, ETSI EN
300 220-1 V1.3.1: 2000-09, ETSI EN 301
489-1 V1.4.1: 2002-08, ETSI EN 301
489-3 V1.4.1: 2002-08
Belgium INCERT B-509-0054
Listings and Approvals:
X
Complies with: EN50131-1 Grade 2, Environmental class II
Installation/Configuration Notes
Compatibility Information
The wireless Local SecurityNetwork (wLSN) including the
wLSN Relay Module is compatible with the Easy Series
Control Panel.
Mounting Considerations
Mount the relay module on interior walls or ceilings where
it is protected from weather elements such as rain or snow.
Note Installation on metal surfaces can affect the RF
propagation pattern of the radio transceiver.
The RF transceiver has a range of approximately 1000 m
(3000 ft) in open air. However, in normal operation, the
actual RF range depends on building construction.
Parts Included
Quant. Component
1 Relay module
4 AA batteries (P/N: 16556)
1 Hardware pack
1 Literature pack
Bosch Security Systems B.V. www.boschsecurity.com
8