Mitsubishi Electronics QD77MS16 Home Security System User Manual


  Open as PDF
of 1038
 
13 - 4
Chapter 13 Control Sub Functions
13.2 Sub functions specifically for machine OPR
The sub functions specifically for machine OPR include the "OPR retry function" and
"OP shift function". Each function is executed by parameter setting.
13.2.1 OPR retry function
When the workpiece goes past the OP without stopping during positioning control, it
may not move back in the direction of the OP although a machine OPR is commanded,
depending on the workpiece position. This normally means the workpiece has to be
moved to a position before the near-point dog by a JOG operation, etc., to start the
machine OPR again. However, by using the OPR retry function, a machine OPR can
be carried out regardless of the workpiece position.
The details shown below explain about the "OPR retry function".
[1] Control details
[2] Precautions during control
[3] Setting the OPR retry function
[1] Control details
The following drawing shows the operation of the OPR retry function.
(1) OPR retry point return retry operation when the workpiece is within the
range between the upper and lower limits.
1) The movement starts in the "[Pr.44] OPR direction" by a machine OPR start.
2) The operation decelerates when the limit signal OFF is detected.
3) After stopping due to the limit signal OFF detection, the operation moves at the "[Pr.46] OPR speed" in the
opposite direction of the "[Pr.44] OPR direction".
4) The operation decelerates when the near-point dog turns OFF.
5) After stopping due to the near-point dog OFF, a machine OPR is carried out in the "[Pr.44] OPR direction".
6) Machine OPR completion
5)
1)
Near-point dog
Limit signal OFF
ON
2)
3)6)
4)
Zero signal
Hardware limit switch
Fig. 13.1 OPR retry operation by limit signal detection